TECHNET Archives

April 2015

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Cables, Tim" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Cables, Tim
Date:
Tue, 21 Apr 2015 14:16:07 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (46 lines)
Thanks, Wayne,
	If anyone has any other thoughts on this please comment.
Regards
Tim Cables
PCB Design

Aclara

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Wayne Thayer
Sent: Tuesday, April 21, 2015 10:05 AM
To: [log in to unmask]
Subject: Re: [TN] Tooling hole to Artwork tolerance

Hi Tim-

This is a derived specification. The PCB fabricators understand this as requirements on the annular ring of a drilled and plated through hole. Look up stuff related to "break-out". I think Class 2 requires no more than 90% breakout, but many customers separately specify "NBO" for No BreakOut.
There's really not much of a difference between these if you're a fabricator, as long as "teardrops" or "snowmen" are allowed on the artwork.

Anyway, the breakout spec controls the total mis-alignment between the drilling process and final conductor formation process (be that etching or additive plating). If the tolling holes/artwork are too mis-aligned, the fabricator won't make the breakout spec. 

Sophisticated board designers know this inherently, so if they want a board to have high accuracy of artwork to tooling holes, they'll have some plated through holes with whatever minimum annular ring the PCB fabricator will commit to.

Wayne Thayer

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Cables, Tim
Sent: Tuesday, April 21, 2015 9:46 AM
To: [log in to unmask]
Subject: [TN] Tooling hole to Artwork tolerance

Can anyone tell me what the IPC spec is for this and which standard it is listed in?


Tim


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2