Subject: | |
From: | |
Reply To: | |
Date: | Thu, 23 Apr 2015 17:49:26 +0000 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Seems like tenting the via will fill that, but I'm not sure it is "guaranteed" to fill it all the time, nor wick down into the hole--but for such a small hole I don't think it would have to flow across it. I use 0.015" vias as a rule, and the majority of time they are sealed--but once in a while boards from a vendor (not sure which) won't, must be a really thin soldermask or they must be doing a pullback or something.
Shawn Upton
Section Head, Test Engineering
Sensors Business Unit
Allegro MicroSystems, LLC
[log in to unmask]
603.626.2429/fax: 603.641.5336
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steven Kelly
Sent: Thursday, April 23, 2015 10:13 AM
To: [log in to unmask]
Subject: [TN] Via Fill
Hi All,
Do you think it is feasible to do non-conductive via fill on a .0025- .003 finished hole size - overall thickness is .028. Regards Steve
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|