Watching this thread.
Ed Popielarski
Engineering Manager
970 NE 21st Ct.
Oak Harbor, Wa. 98277
Ph: 360-675-1322
Fx: 206-624-0695
Cl: 949-581-6601
“It's one kind of victory to slay a beast, move a mountain, and cross a chasm, but it's another kind altogether to realize that the beast, the mountain, and the chasm were of your own design.”
https://maps.google.com/maps/myplaces?hl=en&ll=48.315753,-122.643578&spn=0.011188,0.033023&ctz=420&t=m&z=16&iwloc=A
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Douglas Pauls
Sent: Wednesday, April 15, 2015 1:23 PM
To: [log in to unmask]
Subject: [TN] Viscosity Cups
Good afternoon all,
I have a silly question. We conformally coat using a common solvent based acrylic coating. One process control method is to periodically measure coating viscosity using a Zahn #2 cup, which works well for this particular coating that has about a 55-60 second flow. I am finding that when this coating is thinned down for spray, the times are down in the 15-18 second range and the variation is increasing.
So, my question - is there a style of viscosity dip cup, e.g. Ford, DIN, etc., that is more amenable to thin viscosity coatings? It is understood that a precision instrument like a Brookfield viscometer would be preferrable, but production is NOT going to let me get a few dozen of them.
Thanks.
Doug Pauls
Principal Materials and Process Engineer Rockwell Collins
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]