TECHNET Archives

March 2015

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Sender:
X-To:
Date:
Tue, 31 Mar 2015 19:34:06 +0000
Reply-To:
TechNet E-Mail Forum <[log in to unmask]>, "Upton, Shawn" <[log in to unmask]>
Message-ID:
Subject:
From:
"Upton, Shawn" <[log in to unmask]>
MIME-Version:
1.0
In-Reply-To:
Content-Transfer-Encoding:
quoted-printable
Content-Type:
text/plain; charset="us-ascii"
Parts/Attachments:
text/plain (33 lines)
I have always read it as that way, in the Z direction, I could use the internal spacing from column B1.  If I'm reading it wrong then I'd like to know also.

Shawn Upton
Section Head, Test Engineering
Sensors Business Unit
Allegro MicroSystems, LLC
[log in to unmask]
603.626.2429/fax: 603.641.5336

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Victor Hernandez
Sent: Tuesday, March 31, 2015 2:59 PM
To: [log in to unmask]
Subject: [TN] IPC-2221, Generic Standard on Printed Board Design

Fellow TechNetters:

   I am requesting clarification on the above stated document section 6.3 Electrical Clearance.   The minimum spacing between conductors, between conductive patterns, layer to layer conductive spaces (z=axis), and between conductive materials (such as conductive markings or mounting hardware) and conductors shall be in accordance with Table 6-1, and defined on the master drawing"."

Does this implies that the spacing is also true in the vertical, z=axis, direction as measured in a typical cross section.

Victor,


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2