Victor,
The test you are looking for is UL Flammability Test 94. Most call out the
vertical burn test. CC-830 calls out the Horizontal Burn test.
There is an ASTM method (D635) that is called out by MIL-I-46058 on
coatings, but the UL test is far more widely specified.
Doug Pauls
Principal Materials and Process Engineer
Rockwell Collins