Ioan,

I've done incoming testing of adhesives for many years.  

As others have said, the vendor data sheets will tell you what speed and spindle they are using to do their acceptance testing.

Unfortunately, just because vendor A uses one combination of speed and spindle, doesn't mean that all will.  You will need a variety of spindles, maybe some cone/plate, etc.  each Brookfield will have a speed range.  For some materials you will want a constant temperature bath

FWIW - I don't ever recall taking issue with viscosity unless there was an obvious shipping problem - like all the dry ice melted on a hot Summer trip across the country, etc.  If you are measuring viscosity for internal Manufacturing purposes, then of course you should get a unit.

If you are dealing with reputable adhesives vendors, it is my opinion that you are not adding much value by measuring viscosity and many other parameters.  


Steve C

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Amol Kane
Sent: Thursday, October 09, 2014 11:10 AM
To: [log in to unmask]
Subject: Re: [TN] Viscometer

Schlumberger-Private
________________________________________
Also find out specifically how they test their product (what speed and spindles they use) so that you can buy a unit that can handle the requirements.

Regards,
Amol
  

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Drew meyer
Sent: Thursday, October 09, 2014 8:28 AM
To: [log in to unmask]
Subject: Re: [TN] Viscometer

Ioan,

You may want to check with vendors of the epoxies to see what type of viscometer the use.  I know for solder paste the spiral viscometer is recommended.  We use a Malcom and have been happy with it.

Drew

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
Sent: Thursday, October 09, 2014 8:21 AM
To: [log in to unmask]
Subject: Re: [TN] Viscometer

Hi Ioan,

The old standard, Brookfield...

Steve

On Thu, Oct 9, 2014 at 6:08 AM, Ioan TEMPEA <[log in to unmask]>
wrote:

> Dear Technos,
>
> I need to buy a viscometer, what are your suggestions?
>
> The main usage will be testing conductive epoxies, but might be used 
> for other materials too.
>
> Thanks,
>
> Ioan Tempea, P. Eng.
> Manufacturing Engineer, Satellite Systems
>
> [cid:[log in to unmask]]
>
> MacDonald, Dettwiler and Associates Corporation, 21025 Trans-Canada 
> Highway, Ste-Anne-de-Bellevue, QC, Canada H9X 3R2
> Tel: +1-514-457-2150 x3556
> www.mdacorporation.com<http://www.mdacorporation.com/>
>
> This e-mail, and any attachments, are intended solely for the use of 
> the intended recipient(s) and may contain legally privileged, 
> proprietary and/or confidential information. Any use, disclosure, 
> dissemination, distribution or copying of this e-mail and any 
> attachments for any purposes that have not been specifically 
> authorized by the sender is strictly prohibited. If you are not the 
> intended recipient, please immediately notify the sender by reply 
> e-mail and permanently delete all copies and attachments. This email 
> is for informational purposes only and shall not be interpreted to 
> authorize or conclude a binding agreement between MDA and any other 
> party unless this email contains or is accompanied by an express 
> written confirmation of MDA's intention to enter into a binding 
> agreement, such confirmation shall only be provided by an authorized representative of MDA.
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or 
> [log in to unmask] 
> ______________________________________________________________________
>

-- 


This email and any attachments are only for use by the intended
recipient(s) and may contain legally privileged, confidential, proprietary or otherwise private information. Any unauthorized use, reproduction, dissemination, distribution or other disclosure of the contents of this e-mail or its attachments is strictly prohibited. If you have received this email in error, please notify the sender immediately and delete the original. 


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2