Victor, 

You can also refer to IPC A-610E par. 7.3.5.9 pag. 7-53.

Francesco
Francesco Di Maio 
IPC A-600, IPC A-610, IPC 7711/21 Certified IPC Trainer





"Gumpert, Ben" <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]>
05/08/2014 15.56
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
"Gumpert, Ben"  <[log in to unmask]>


To
<[log in to unmask]>
cc

Subject
Re: [TN] Post solder Component lead trimming






Victor,

J-STD-001 Rev E Para. 6.1.4 states that leads trimmed shall have the 
solder reflowed or inspected at 10X for damage.
And if the trim cuts into the solder fillet, it must be reflowed.

Ben

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Victor Hernandez
Sent: Tuesday, August 05, 2014 9:33 AM
To: [log in to unmask]
Subject: EXTERNAL: [TN] Post solder Component lead trimming

Fellow TechNetters:

   Does IPC Standards address the lead trimming of components on post 
solder assemblies.   I heard that on post solder lead trimming that a 
second pass solder operation is required to ensure solder joint integrity 
from the lead trimming process.   Any comments and/or direction for 
literature review.

Victor,


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________



______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2