IPC-600 3.2 is used primarily to show what the results and shapes of etched traces will be using various resist methods.
From a fabricator's standpoint, it depends on the Chemistry and process they use.
From a design/customer standpoint, it is always best to allow the fabricator to "add" the etch factor to fabrication files. A designer/ customer should be, however, aware of etch factor ranges so the initial designs leave enough room to allow for it. In general, I believe most fabricators will be around .001" per oz. weight copper (or less). This means an etched line on 1 oz. copper will end up .001" narrower than the file used to create the etched line.
I hope this helps.
Mike Lehmicke
Project Engineer
Printed Circuit Products
Molex Incorporated
22 Empire Drive
St. Paul, MN 55103
651-846-7728
[log in to unmask]
Warning - Information included in this email and /or in any attachments herein may be subject to the EAR (15 CFR 730-774) and/or ITAR (22 CFR 120-130) Regulations.
The recipient acknowledges their responsibility for compliance with all Export Administration Regulations & ITAR regulations regarding the handling and/or export of any Molex products and technical information; including the disclosure to any Foreign Nationals.
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Mordechai Kirshenbaum
Sent: Thursday, August 07, 2014 10:26 AM
To: [log in to unmask]
Subject: [TN] Minimum allowed Etch Factor
Dear Sir
Dear Sir
Is there a criteria or a requirement for the minimum allowed "etch factor”
i.e. the ratio of the depth of etch to the amount of lateral etch as defined by # 3.2 of IPC-A-600
and depicted in fig IPC-600g-321a.
Mordechai
________________________________
CONFIDENTIALITY NOTICE: This message (including any attachments) may contain Molex confidential information, protected by law. If this message is confidential, forwarding it to individuals, other than those with a need to know, without the permission of the sender, is prohibited.
This message is also intended for a specific individual. If you are not the intended recipient, you should delete this message and are hereby notified that any disclosure, copying, or distribution of this message or taking of any action based upon it, is strictly prohibited.
English | Chinese | Japanese
www.molex.com/confidentiality.html
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|