CALCE is active in small and smart thermo fluidic systems research with 20+ peer 
reviewed journal publications in 2013.

On 7/18/2014 8:49 PM, Bev Christian wrote:
> CALCE was doing work on this. Not sure if they still are.
> Regards,
> Bev
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Bob Landman
> Sent: Thursday, July 17, 2014 5:24 PM
> To: [log in to unmask]
> Subject: Re: [TN] LIst of thermal conduction effective design
>
> Wayne,
>
> I just Googled 'microfluidic heat pipes", besides one of my alma maters
> (UCSB) Columbia, Duke, Stanford and many others are doing R&D it appears
> some manufacturers can make them in PC boards.
>
> See https://www.youtube.com/watch?v=7TQCOEXQaYA
>
> Bob
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Wayne Thayer
> Sent: Thursday, July 17, 2014 1:13 PM
> To: [log in to unmask]
> Subject: Re: [TN] LIst of thermal conduction effective design
>
> I believe UCSB is working on microfluidic heat pipes and has had some
> success. But from university to practicality is a long journey! CIC cores
> will be with us for many years.
>
> Are you trying to just spread, or do you have somewhere for this heat to go?
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Yuan-chia Joyce Koo
> Sent: Thursday, July 17, 2014 11:25 AM
> To: [log in to unmask]
> Subject: Re: [TN] LIst of thermal conduction effective design
>
> thanks bob and wayne.  I am more intend to looking for next gen tech, such
> as phase transition material build in core of the PWB.  with high density
> and super hot chip down to the road with compound semi, something need to be
> addressed on the thermal side.  Yes, I am fully aware of the FEM power,
> however, the limitation still in  the thermal  conduction - BN and diamond
> coating are still pricy and not compatible to many of the HDI cct.  Just try
> to see if there is any new trick out there.  Thanks again.
> Best regards,
>             joyce
> On Jul 17, 2014, at 9:40 AM, Bob Landman wrote:
>
>> Hi Joyce,
>>
>> Well, even PC's these days esp. with very powerful processors) use
>> heat pipes.  Of course they also use huge fans.  (warning! Pun
>> ahead!!)
>>
>> What's really cool about heat pipes is they spread the heat and
>> conduct it to the exterior of the enclosure where there can be a
>> radiator.  My Apple MacBook Air gets so hot I can't rest it on my lap!
>> The aluminum case spreads the heat.  There is a tiny fan inside but
>> the fan's vents are under the laptop so if you do place it on your
>> lap, or when it bed reading, on a pillow, the vents are blocked.
>> Haven't had it crash on me "yet".  Why they didn't put the vents on
>> the sides? Esthetics, I'll bet, knowing Steve Jobs.
>>
>> E,g, http://www.thermacore.com/industries/communications.aspx
>> http://www.aavid.com/product-group/microprocessors/notebook
>>
>> They offer design assistance.
>>
>> Bob
>>
>>
>> -----Original Message-----
>> From: TechNet [mailto:[log in to unmask]] On Behalf Of Wayne Thayer
>> Sent: Thursday, July 17, 2014 9:20 AM
>> To: [log in to unmask]
>> Subject: Re: [TN] LIst of thermal conduction effective design
>>
>> Hi Joyce-
>>
>> Basically, you have to model the bejeesus out of the arrangement.
>> Nowadays that modeling is CFD (Computational Fluid Dynamics). Big
>> finite element model. And you really need a physical model in addition
>> to make sure all of the fudge factors are properly calculated. Then,
>> after you begin production, you will find your customer changed
>> something in the environment which rendered most of the modeling moot!
>> Getting good representations for actual airflow in the application can
>> be difficult to do also.
>>
>> If you are longer on time and short on money, a bunch of physical
>> models can also get you there, but if you are going to be playing with
>> the number of copper planes in the pcb that can get expensive too.
>> Used to be that someone, like a university, would run a bunch of those
>> kinds of modeling tests and publish results so you could interpolate
>> for your problem, but not any more: the math models have taken over.
>>
>> Wayne
>>
>> -----Original Message-----
>> From: TechNet [mailto:[log in to unmask]] On Behalf Of Yuan-chia Joyce
>> Koo
>> Sent: Thursday, July 17, 2014 6:34 AM
>> To: [log in to unmask]
>> Subject: [TN] LIst of thermal conduction effective design
>>
>> Gurus,
>> The most challenge in my short career of 24 years is application of
>> thermal
>> components:  the requirements just go up non stop.  How do you handle
>> the thermal load in terms of static,  dynamic or transient thermal
>> load on high density PWB/PWA, besides known build in heat sink.  I am
>> seeking for the low provide conduction type, with limited or no
>> convection cooling.  Many thanks.
>> (IBM's metal backing PWB is nice, but for multi-layer, >8 is a bit
>> difficult. Besides, double side or high density might have some
>> limitation - any new development in the field? ) Thanks in advance.
>> (net a bit quiet, I guess many on summer vacation mode with BBQ  ;-).
>>               joyce
>>
>>
>> ______________________________________________________________________
>> This email has been scanned by the Symantec Email Security.cloud
>> service.
>> For more information please contact helpdesk at x2960 or
>> [log in to unmask]
>> ______________________________________________________________________
>>
>>
>>
>> ______________________________________________________________________
>> This email has been scanned by the Symantec Email Security.cloud
>> service.
>> For more information please contact helpdesk at x2960 or
>> [log in to unmask]
>> ______________________________________________________________________
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________

-- 

Bhanu Sood

Center for Advanced Life Cycle Engineering (CALCE)
Test Services and Failure Analysis Laboratory
Room 0128, Glenn L. Martin Hall (Building 088)
University of Maryland
College Park, MD 20742

Tel: +1 (301) 405 3498
Fax: +1 (301) 314 9269
e-mail: [log in to unmask]
Skype: calce_umd
website: www.calce.umd.edu/TSFA
  
Confidentiality Notice: The information contained in this e-mail
and any attachments may be legally privileged and confidential.
If you are not an intended recipient, you are hereby notified that
any dissemination, distribution or copying of this e-mail is strictly
prohibited. If you have received this e-mail in error, please notify
the sender and permanently delete the e-mail and any attachments
immediately. You should not retain, copy or use this e-mail or
any attachment for any purpose, nor disclose all or any part of the
contents to any other person.


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2