Henry Rekers <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, [log in to unmask]
Date:
Tue, 10 Jun 2014 14:31:45 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (257 lines)
That's the secondary drill process....not allowed in our specification.
_____________________________________________________________________________________ 


Henry Rekers P. Eng |   Schneider Electric   |  Global Supply Chain  |   
Senior Manufacturing Engineer
Phone: +1-250-652-7100 ext. 7510  |   Toll Free: +1-866-466-7627 ext. 
7510  |   Fax: +1-250-544-2390  |   
Email: [log in to unmask]  |   Site: 
www.schneider-electric.com  |   Address: 2195 Keating Cross Road, 
Saanichton, BC, Canada, V8M 2A5 
*** Please consider the environment before printing this e-mail



From:
Steven Kelly <[log in to unmask]>
To:
<[log in to unmask]>, 
Date:
06/10/2014 01:54 PM
Subject:
Re: [TN] Plating in non-plated holes - again
Sent by:
TechNet <[log in to unmask]>



The supplier could drill these after ENIG - no violation to any 
specification. My 2 cents. Steve Kelly

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Henry Rekers
Sent: June-10-14 4:36 PM
To: [log in to unmask]
Subject: Re: [TN] Plating in non-plated holes - again

I agree, we do not allow secondary drilling on the first pass for 
registration issues.  We would allow rework, but not as a practice, and 
our concern would be the tolerance on the hole, both registration and 
diameter.

Could you point me out in 6012 where copper smear is not allowed?  I 
couldn't find that.

Thanks.
_____________________________________________________________________________________ 



Henry Rekers P. Eng |   Schneider Electric   |  Global Supply Chain  | 
Senior Manufacturing Engineer
Phone: +1-250-652-7100 ext. 7510  |   Toll Free: +1-866-466-7627 ext. 
7510  |   Fax: +1-250-544-2390  | 
Email: [log in to unmask]  |   Site: 
www.schneider-electric.com  |   Address: 2195 Keating Cross Road, 
Saanichton, BC, Canada, V8M 2A5
*** Please consider the environment before printing this e-mail



From:
"Stadem, Richard D." <[log in to unmask]>
To:
<[log in to unmask]>, 
Date:
06/10/2014 12:43 PM
Subject:
Re: [TN] Plating in non-plated holes - again
Sent by:
TechNet <[log in to unmask]>



While secondary drilling prohibitions do apply to drilling of the original 

holes after plating, they were not intended to apply to rework of the 
original holes which were drilled as primary (prior to plating) as long as 

the rework does not result in the hole being out of tolerance, either in 
hole diameter or location from datum registration point X0, Y0. 

Remember, rework means returning the original non-conforming 
characteristic to meet all applicable requirements.

If they ended up with plating inside pre-drilled holes that is not 
supposed to be there, how would the fabricator then rework those holes to 
meet the fabricated print requirements if a strict prohibition of 
secondary drilling were applied?  Does that mean I cannot take a dental 
pick and lightly scrape away a copper sliver after plating is completed?

I am not talking about increasing the hole size, just using the same size 
bit (or etchant) to clean out any excess copper.

Just call it touchup. 

The limitation of no secondary drilling was intended to prevent 
mis-registration and exposed inner layer copper and smearing, as you 
pointed out. But cleaning the extraneous copper from the holes already 
drilled is not likely to cause any mis-registration at that later step. 
Per 6012, any copper smear inside the unplated holes is considered a 
defect condition. 

It does not say "Well, maybe a wee widdle bit is OK."


-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]] 
Sent: Tuesday, June 10, 2014 1:38 PM
To: [log in to unmask]; Stadem, Richard D.
Subject: RE: [TN] Plating in non-plated holes - again

I know I am late chiming in, but how are non-plated through holes not 
secondary drilling requirements?  Your drawing requirement for NPTH would 
supercede any fabrication specification.  Or am I wrong?

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.
Sent: Tuesday, June 10, 2014 11:35 AM
To: [log in to unmask]
Subject: Re: [TN] Plating in non-plated holes - again

Secondary drilling of holes already drilled is not secondary drilling, 
however. It is rework. Rework of defects that should have been found and 
fixed in the first place.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Henry Rekers
Sent: Tuesday, June 10, 2014 10:52 AM
To: [log in to unmask]
Subject: Re: [TN] Plating in non-plated holes - again

I'd love to do that, but our specification demands no secondary drilling.
My guess is due to past registration issues.
_____________________________________________________________________________________


Henry Rekers P. Eng |   Schneider Electric   |  Global Supply Chain  |
Senior Manufacturing Engineer
Phone: +1-250-652-7100 ext. 7510  |   Toll Free: +1-866-466-7627 ext.
7510  |   Fax: +1-250-544-2390  |
Email: [log in to unmask]  |   Site:
www.schneider-electric.com  |   Address: 2195 Keating Cross Road,
Saanichton, BC, Canada, V8M 2A5
*** Please consider the environment before printing this e-mail



From:
Brian Ellis <[log in to unmask]>
To:
TechNet E-Mail Forum <[log in to unmask]>,
[log in to unmask],
Date:
06/10/2014 08:38 AM
Subject:
Re: [TN] Plating in non-plated holes - again



Drill after ENIG

Brian

On 10.06.2014 18:26, Henry Rekers wrote:
> Hey there technetters.  A while back, I sent a message about enig
plating
> contamination in NON-plated holes.   I've bounced it back to the board
> shop saying that it is unacceptable, but they claim it is due to 6012
> 3.5.2
> I also think it's unacceptable in the 4552 spec.   The design
> documentation clearly states non-plated.   It's not plated, just
partially
> plated.
>
> Any advice?
>
> Thanks.
>
_____________________________________________________________________________________
>
>
> Henry Rekers P. Eng |   Schneider Electric   |  Global Supply Chain  |
> Senior Manufacturing Engineer
> Phone: +1-250-652-7100 ext. 7510  |   Toll Free: +1-866-466-7627 ext.
> 7510  |   Fax: +1-250-544-2390  |
> Email: [log in to unmask]  |   Site:
> www.schneider-electric.com  |   Address: 2195 Keating Cross Road,
> Saanichton, BC, Canada, V8M 2A5
> *** Please consider the environment before printing this e-mail
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud
service.
> For more information please contact helpdesk at x2960 or
[log in to unmask]
> ______________________________________________________________________
>

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
______________________________________________________________________




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________
________________________________
 This message and any attachments are solely for the use of the addressee 
and may contain L-3 proprietary information that may also be defined as 
USG export controlled technical data. If you are not the intended 
recipient, any disclosure, use or distribution of its content is 
prohibited. Please notify the sender by reply e-mail and immediately 
delete this message and any attachments.

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
______________________________________________________________________




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
______________________________________________________________________




______________________________________________________________________