Hi Henry,
 
What is the diameter of NPTH?
 
Best regards,
 
Gerry
 
> Date: Tue, 10 Jun 2014 11:25:39 -0700
> From: [log in to unmask]
> Subject: Re: [TN] Plating in non-plated holes - again
> To: [log in to unmask]
> 
> That's what I think, but we're getting push back from the supplier and I 
> was hoping to get more specific. 
> 
> Thanks.
> 
> _____________________________________________________________________________________ 
> 
> 
> Henry Rekers P. Eng |   Schneider Electric   |  Global Supply Chain  |   
> Senior Manufacturing Engineer
> Phone: +1-250-652-7100 ext. 7510  |   Toll Free: +1-866-466-7627 ext. 
> 7510  |   Fax: +1-250-544-2390  |   
> Email: [log in to unmask]  |   Site: 
> www.schneider-electric.com  |   Address: 2195 Keating Cross Road, 
> Saanichton, BC, Canada, V8M 2A5 
> *** Please consider the environment before printing this e-mail
> 
> 
> 
> From:
> David Hillman <[log in to unmask]>
> To:
> <[log in to unmask]>, 
> Date:
> 06/10/2014 10:08 AM
> Subject:
> Re: [TN] Plating in non-plated holes - again
> Sent by:
> TechNet <[log in to unmask]>
> 
> 
> 
> Hi Henry - maybe I am making this too simple but if your drawing/design
> data shows a nonplated thru hole, then having any plating in it, partial 
> or
> complete, is a violation of the drawing and therefore a nonconformance.
> 
> Dave
> 
> 
> On Tue, Jun 10, 2014 at 10:26 AM, Henry Rekers <
> [log in to unmask]> wrote:
> 
> > Hey there technetters.  A while back, I sent a message about enig 
> plating
> > contamination in NON-plated holes.   I've bounced it back to the board
> > shop saying that it is unacceptable, but they claim it is due to 6012
> > 3.5.2
> > I also think it's unacceptable in the 4552 spec.   The design
> > documentation clearly states non-plated.   It's not plated, just 
> partially
> > plated.
> >
> > Any advice?
> >
> > Thanks.
> >
> > 
> _____________________________________________________________________________________
> >
> >
> > Henry Rekers P. Eng |   Schneider Electric   |  Global Supply Chain  |
> > Senior Manufacturing Engineer
> > Phone: +1-250-652-7100 ext. 7510  |   Toll Free: +1-866-466-7627 ext.
> > 7510  |   Fax: +1-250-544-2390  |
> > Email: [log in to unmask]  |   Site:
> > www.schneider-electric.com  |   Address: 2195 Keating Cross Road,
> > Saanichton, BC, Canada, V8M 2A5
> > *** Please consider the environment before printing this e-mail
> >
> > ______________________________________________________________________
> > This email has been scanned by the Symantec Email Security.cloud 
> service.
> > For more information please contact helpdesk at x2960 or 
> [log in to unmask]
> > ______________________________________________________________________
> >
> 
> 
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask] 
> ______________________________________________________________________
> 
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> ______________________________________________________________________
> 
> 
> 
> 
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask] 
> ______________________________________________________________________
 		 	   		  

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.