That's what I think, but we're getting push back from the supplier and I
was hoping to get more specific.
Thanks.
_____________________________________________________________________________________
Henry Rekers P. Eng | Schneider Electric | Global Supply Chain |
Senior Manufacturing Engineer
Phone: +1-250-652-7100 ext. 7510 | Toll Free: +1-866-466-7627 ext.
7510 | Fax: +1-250-544-2390 |
Email: [log in to unmask] | Site:
www.schneider-electric.com | Address: 2195 Keating Cross Road,
Saanichton, BC, Canada, V8M 2A5
*** Please consider the environment before printing this e-mail
From:
David Hillman <[log in to unmask]>
To:
<[log in to unmask]>,
Date:
06/10/2014 10:08 AM
Subject:
Re: [TN] Plating in non-plated holes - again
Sent by:
TechNet <[log in to unmask]>
Hi Henry - maybe I am making this too simple but if your drawing/design
data shows a nonplated thru hole, then having any plating in it, partial
or
complete, is a violation of the drawing and therefore a nonconformance.
Dave
On Tue, Jun 10, 2014 at 10:26 AM, Henry Rekers <
[log in to unmask]> wrote:
> Hey there technetters. A while back, I sent a message about enig
plating
> contamination in NON-plated holes. I've bounced it back to the board
> shop saying that it is unacceptable, but they claim it is due to 6012
> 3.5.2
> I also think it's unacceptable in the 4552 spec. The design
> documentation clearly states non-plated. It's not plated, just
partially
> plated.
>
> Any advice?
>
> Thanks.
>
>
_____________________________________________________________________________________
>
>
> Henry Rekers P. Eng | Schneider Electric | Global Supply Chain |
> Senior Manufacturing Engineer
> Phone: +1-250-652-7100 ext. 7510 | Toll Free: +1-866-466-7627 ext.
> 7510 | Fax: +1-250-544-2390 |
> Email: [log in to unmask] | Site:
> www.schneider-electric.com | Address: 2195 Keating Cross Road,
> Saanichton, BC, Canada, V8M 2A5
> *** Please consider the environment before printing this e-mail
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud
service.
> For more information please contact helpdesk at x2960 or
[log in to unmask]
> ______________________________________________________________________
>
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|