Hello Gil,

I have seen similar condition on a thermistor soldered on ENIG PCB using 
SAC405.

It was the only component that had all the solder attached on the 
metallization and not on the pad surface that showed the dewetting 
condition.

The analyses performed at that time, identified that component finishing 
were  Pd-Ag-Pt (Palladium - Silver - Platinum).
At that time the problem was solved by the Component Supplier changing 
this component with another having another finishing.

Hope this can help in understanding your problem.

Regards.
Francesco 
Francesco Di Maio 
IPC e Formazione
IPC A-600, IPC A-610, IPC 7711/21 Certified IPC Trainer

E-Mail:[log in to unmask]




Zilber Gil <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]>
03/06/2014 21.21
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
Zilber Gil      <[log in to unmask]>


To
<[log in to unmask]>
cc

Subject
[TN] השב: [TN] Capacitor - strange soldering behavior






Yes they pass but after the test the surface is grey and poros.
Thanks,

Gil


-------- הודעה מקורית --------
מאת: [log in to unmask]
תאריך:03/06/2014 2:20 PM (GMT+02:00)
אל: [log in to unmask],Zilber Gil
עותק: [log in to unmask]
נושא: RE: [TN] Capacitor - strange soldering behavior

Do the ceramic caps pass Solderability by themselves?

Victor,

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Zilber Gil
Sent: Monday, June 02, 2014 4:37 PM
To: [log in to unmask]
Subject: [TN] השב: [TN] Capacitor - strange soldering behavior

This Ceramic Cap is from different company. Looks good before soldering.
Thanks,
Gil


-------- הודעה מקורית --------
מאת: Reuven Rokah
תאריך:02/06/2014 10:31 PM (GMT+02:00)
אל: [log in to unmask]
נושא: Re: [TN] Capacitor - strange soldering behavior

Hi Gil,

It seems a component plating failure.
Try to check what is the difference between this capacitor and other one 
with good performance.
It seems your problematic cap. have grainy structure plating which that 
suck the solder during the solder joint.
Try to work with 220 deg C.


On Mon, Jun 2, 2014 at 6:12 PM, Zilber Gil wrote:

> XRF was done on a new part before reflow. Before reflow the surface
> was shine. After reflow it was grayed and porous as seen in the picture.
> Thanks,
>
> Gil
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Victor Hernandez
> Sent: Monday, June 02, 2014 6:06 PM
> To: [log in to unmask]
> Subject: Re: [TN] Capacitor - strange soldering behavior
>
> Would XRF plating alloy identification work here on a loose part?
>
> Victor,
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of David Hillman
> Sent: Monday, June 02, 2014 9:36 AM
> To: [log in to unmask]
> Subject: Re: [TN] Capacitor - strange soldering behavior
>
> Hi Gil - two questions: (1) Does the capacitor have a barrier layer of
> copper or nickel to prevent the underlying metallization from leaching
> into the solder joint?; (2) Have you completed a cross section to
> assess the solder joint microstructure?
>
> Dave Hillman
> Rockwell Collins
> [log in to unmask]
>
>
> On Thu, May 29, 2014 at 9:01 AM, Zilber Gil wrote:
>
> > Hello Technet,
> >
> > While soldering this ceramic capacitor (
> > http://ipc-technet.groupsite.com/gallery/27235), its looks like that
> > the capacitor suck the solder from the PCB`s pad to the capacitor
> > pad and the color is now grayish and porosity. XRF found Sn, Pb, Cu
> > on the capacitor pad. PCB Solderability was good and the profile was
> > SnPb at
> > 225 deg C under Nitrogen. Other capacitors and components on the
> > board look normal with shine soldering.
> > Can anybody seen something like that before? Any ideas?
> >
> > Thanks and have a wonderful weekend.
> >
> > Dr. Gil Zilber
> > Technologist, Elta system Ltd.
> >
> >
> > The information contained in this communication is proprietary to
> > Israel Aerospace Industries Ltd. and/or third parties, may contain
> > confidential or privileged information, and is intended only for the
> > use of the intended addresse thereof. If you are not the intended
> > addressee, please be aware that any use, disclosure, distribution
> > and/or copying of this communication is strictly prohibited. If you
> > receive this communication in error, please notify the sender
> immediately and delete it from your computer.
> >
> > Thank you.
> >
> >
> > ____________________________________________________________________
> > __ This email has been scanned by the Symantec Email Security.cloud
> > service.
> > For more information please contact helpdesk at x2960 or
> > [log in to unmask]
> > ____________________________________________________________________
> > __
> >
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud 
service.
> For more information please contact helpdesk at x2960 or
> [log in to unmask]
> ______________________________________________________________________
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud 
service.
> For more information please contact helpdesk at x2960 or
> [log in to unmask]
> ______________________________________________________________________
> The information contained in this communication is proprietary to
> Israel Aerospace Industries Ltd. and/or third parties, may contain
> confidential or privileged information, and is intended only for the
> use of the intended addresse thereof. If you are not the intended
> addressee, please be aware that any use, disclosure, distribution
> and/or copying of this communication is strictly prohibited. If you
> receive this communication in error, please notify the sender 
immediately and delete it from your computer.
>
> Thank you.
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud 
service.
> For more information please contact helpdesk at x2960 or
> [log in to unmask]
> ______________________________________________________________________
>



--

Best Regards,

*Reuven Rokah*

Mobile: 972-52-6012018
Tel: 972-3-9360688
Fax: 076-5100674
[log in to unmask]
[log in to unmask]
www.rokah-technologies.com


This e-mail message is intended for the recipient only and contains 
information which is CONFIDENTIAL and which may be proprietary of Rokah 
Technologies. If you have received this transmission in error, please 
inform me by e-mail, phone or fax, and then please delete all of the 
original files and all other copies exist.


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________
The information contained in this communication is proprietary to Israel 
Aerospace Industries Ltd. and/or third parties, may contain confidential 
or privileged information, and is intended only for the use of the 
intended addresse thereof. If you are not the intended addressee, please 
be aware that any use, disclosure, distribution and/or copying of this 
communication is strictly prohibited. If you receive this communication in 
error, please notify the sender immediately and delete it from your 
computer.

Thank you.


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________
The information contained in this communication is proprietary to Israel 
Aerospace Industries Ltd. and/or third parties, may contain confidential 
or privileged information, and is intended only for the use of the 
intended addresse thereof. If you are not the intended addressee, please 
be aware that any use, disclosure, distribution and/or copying of this 
communication is strictly prohibited. If you receive this communication in 
error, please notify the sender immediately and delete it from your 
computer.

Thank you.


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________



______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2