Juliano,

We use a four spot humidity indicator card (10%, 20%, 30%, 40%).  Our HIC limit is 20%.  If the 30% changes color, the contents requires baking.  I don't know why you would have an HIC with 60% as an indicator.

Phil

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Datacom - Juliano Ribeiro
Sent: Wednesday, April 30, 2014 1:10 PM
To: [log in to unmask]
Subject: [TN] RES: [TN] PCB Humidity

Thank you Gabriele for your answer, but the IPC1601 don't have an information about what are the maximum level Humidity? Or I didn't find this information.
For example, the components according to thickness are Level 3 or 4 or....
and the PCB Is there table about this?
We need to register in my incoming to verify the HIC, but what's acceptable humidity?

Thank you

_____________________________
Juliano Bettim Ribeiro
DATACOM
ENGENHARIA DE PROCESSOS
Rua América Nº 1000 - Eldorado do Sul - RS CEP: 92990-000
+55 (51) 8446-2135
+55 (51) 3933-3000
Ramal: 3877
[log in to unmask]
www.datacom.ind.br

-----Mensagem original-----
De: SALA GABRIELE [mailto:[log in to unmask]] Enviada em: quarta-feira, 30 de abril de 2014 16:10
Para: 'TechNet E-Mail Forum'; 'Datacom - Juliano Ribeiro'
Assunto: R: [TN] PCB Humidity

Hi Juliano,

this standard gives worthy guidelines:

IPC-1601  Printed Board Handling and Storage Guidelines.

http://www.ipc.org/TOC/IPC-1601.pdf

Gabriele


-----Messaggio originale-----
Da: TechNet [mailto:[log in to unmask]] Per conto di Datacom - Juliano Ribeiro
Inviato: mercoledì 30 aprile 2014 19.57
A: [log in to unmask]
Oggetto: [TN] PCB Humidity

Hi to all,

We received a PCB lot with HIC more than 10% but less than 60%.

What is IPC/JEDEC or others specifications to Humidity limits to PCB?

Is it good or no good PCB?



Thank you

_____________________________

Juliano Bettim Ribeiro

DATACOM

ENGENHARIA DE PROCESSOS
Rua América Nº 1000 - Eldorado do Sul - RS CEP: 92990-000
+55 (51) 8446-2135

+55 (51) 3933-3000

Ramal: 3877
 <mailto:[log in to unmask]> [log in to unmask]
 <http://www.datacom.ind.br/> www.datacom.ind.br




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________


---
Questa e-mail è priva di virus e malware perché è attiva la protezione
avast! Antivirus.
http://www.avast.com


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
________________________________
 This message and any attachments are solely for the use of the addressee and may contain L-3 proprietary information that may also be defined as USG export controlled technical data. If you are not the intended recipient, any disclosure, use or distribution of its content is prohibited. Please notify the sender by reply e-mail and immediately delete this message and any attachments.

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2