It's the engineers and D-bug.  They want to see the ref des.  I put 
them on the assembly drawing only layer when they will not fit and 
provide a searchable PDF assembly drawing, but they still want them 
on the board (and not over vias).  I do my best at 1.25mm height but 
it's good to know that I can drop down to .1 if necessary.  Again, 
it's not for anyone but the engineers and d-bug, everything I do 
pretty much needs to be assembled on the line, no hand assembly will do.

Thanks,

Dave

At 03:58 PM 3/26/2014, you wrote:
>I try to keep my minimum designator text at 1mm with a 0.2mm line 
>thickness. That seems to be achievable & can still be read.
>Beyond that, I leave them off. Boards with small smd components are 
>usually machine loaded anyway. I give priority to designators for 
>connectors and major components.
>No point having the designators use up all the space you are saving 
>by using the 0402s or 0201s. The rear side of my boards behind large 
>BGAs tend to be a 'texture' of 0402 caps - no designators fit.
>regards,
>
>Phil Dutton C.I.D.+
>
>-----Original Message-----
>From: DesignerCouncil [mailto:[log in to unmask]] On Behalf Of 
>David Baldwin
>Sent: Thursday, 27 March 2014 3:30 AM
>To: [log in to unmask]
>Subject: [DC] Smallest Reasonable Ref. Des. Size?
>
>I am finding as I design tighter and tighter boards, especially with 
>0201's, the ref des just no longer fit.  I've been moving ref. des 
>to the assembly layer and leaving them off of the PCB, and where I 
>can, I run leader lines to their positions.  I've been trying to 
>stay with 1.25mm height with .125mm line width.  I know it may vary 
>between board shop capabilities, but what is the smallest reasonable ref.
>des. size that most shops can deal with today.
>
>Thanks,
>
>David Baldwin CID+
>
>
>______________________________________________________________________
>This email has been scanned by the Symantec Email Security.cloud service.
>For more information please contact helpdesk at x2960 or 
>[log in to unmask] 
>______________________________________________________________________
>
>---------------------------------------------------------------------------------
>DesignerCouncil Mail List provided as a free service by IPC using 
>LISTSERV 16.0.
>To unsubscribe, send a message to [log in to unmask] with following 
>text in the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
>To temporarily stop/(restart) delivery of DesignerCouncil send: SET 
>DesignerCouncil NOMAIL/(MAIL) For additional information, or contact 
>Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
>---------------------------------------------------------------------------------
>This email has been sent on behalf of one of the following companies 
>within the BAE Systems Australia group of companies:
>
>     BAE Systems Australia Limited - Australian Company Number 008 423 005
>     BAE Systems Australia Defence Pty Limited - Australian Company 
> Number 006 870 846
>     BAE Systems Australia Logistics Pty Limited - Australian 
> Company Number 086 228 864
>
>Our registered office is Evans Building, Taranaki Road, Edinburgh Parks,
>Edinburgh, South Australia, 5111. If the identity of the sending company is
>not clear from the content of this email please contact the sender.
>
>This email and any attachments may contain confidential and legally
>privileged information.  If you are not the intended recipient, do not copy or
>disclose its content, but please reply to this email immediately and highlight
>the error to the sender and then immediately delete the message.
>
>______________________________________________________________________
>This email has been scanned by the Symantec Email Security.cloud service.
>For more information please contact helpdesk at x2960 or [log in to unmask]
>______________________________________________________________________
>
>---------------------------------------------------------------------------------
>DesignerCouncil Mail List provided as a free service by IPC using 
>LISTSERV 16.0.
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
>To temporarily stop/(restart) delivery of DesignerCouncil send: SET 
>DesignerCouncil NOMAIL/(MAIL)
>For additional information, or contact Keach Sasamori at 
>[log in to unmask] or 847-615-7100 ext.2815
>---------------------------------------------------------------------------------

Via Circuits Inc.

http://www.viacircuits.com
(480) 892-9920  

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 16.0.
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

ATOM RSS1 RSS2