DESIGNERCOUNCIL Archives

February 2014

DesignerCouncil@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Sender:
DesignerCouncil <[log in to unmask]>
X-To:
Designers Council Forum <[log in to unmask]>, Larry Brophy <[log in to unmask]>
Date:
Mon, 24 Feb 2014 15:29:46 +0000
Reply-To:
"(Designers Council Forum)" <[log in to unmask]>, "Yoch, Brian" <[log in to unmask]>
Message-ID:
Subject:
From:
"Yoch, Brian" <[log in to unmask]>
Content-Type:
text/plain; charset="utf-8"
In-Reply-To:
Content-Transfer-Encoding:
base64
MIME-Version:
1.0
Parts/Attachments:
text/plain (1 lines)
According to IPC2221B 9.2.2.3 Tables 9-3 & 9-4 a 4mil laser drilled blind via does not meet Class 3 specs. The minimum size for a buried via is 5.91mils and the minimum blind via is 7.87mils. 

-----Original Message-----
From: DesignerCouncil [mailto:[log in to unmask]] On Behalf Of Larry Brophy
Sent: Monday, February 24, 2014 8:19 AM
To: [log in to unmask]
Subject: [DC] Minimum Via size

Is there a minimum via size for a blind via for Class 3?

I'm working on a design that I will need to use a laser drill of 4 mil.

Thanks,

Larry

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 16.0.
To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL) For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

This message is intended only for the named recipient. If you are not the intended recipient, you are notified that disclosing, copying, distributing or taking any action based on the contents of this information is strictly prohibited.


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________




---------------------------------------------------------------------------------

DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 16.0.

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF DesignerCouncil.

To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)

For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

---------------------------------------------------------------------------------


ATOM RSS1 RSS2