Agreed.
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Inge Hernefjord
Sent: Friday, September 20, 2013 12:57 PM
To: [log in to unmask]
Subject: Re: [TN] CAF, between a signal pint and ground
Because you got two 'YES' I say 'NO'. (I can see many rise eyebrows. What will happen now? The question was 'can there be exothermic damage?'. My njet is based on a special condition, which you may have or not have, namely the impedance of the pathway. Some circuits can have 1. Extremely low voltage 2. Very high resistivity. Such a combination will not produce enough energy to start a exothermic issue. Just a footnote.
Inge