Thinking you can have Quality For Nothing and your chicks for free, leads to a career in dire straits.
Dewey
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of David D. Hillman
Sent: Wednesday, August 07, 2013 11:51 AM
To: [log in to unmask]
Subject: Re: [TN] QFN solder voiding
Hi Bob - I think we can sum up Richard's, your and my experience with QFNs as they require good due diligence and attention to achieve good reliability and manufacturability. The use of QFN components should be properly investigated and characterized prior to implementation on production product. The IPC-7093 standard is a great resource for that task.
Dave
From: Bob Landman <[log in to unmask]>
To: <[log in to unmask]>
Date: 08/07/2013 11:54 AM
Subject: Re: [TN] QFN solder voiding
Sent by: TechNet <[log in to unmask]>
I'm 100% with Dave on this one. We mfg industrial fiberoptic
communications equipment. We can't avoid TQFNs as the laser transmitters
and photodiode receiver ICs are only available in TQFN packages or die (we
do not use die).
I'm checking with the IC manufacturer as the package datasheet isn't clear
about this; that we purchase gold plated padded QFN and TQFN devices.
We specify that 63/37 Sn/Pb water soluable solderpaste be used on our ENIG
boards. An older design is HASL tin/lead.
We've been using these parts since 2002 and have never had a reliability
problem with either the center pad nor peripheral pads. We specify that
the peripheral board pads be slightly extended beyond the package for
probing and assurance that solder is attaching to all the pads. The
center pad is the tricky part. Either a cross of paste or if Mydata paste
jet is used, a thinner layer of paste is applied to the center pad or the
solder on this pad will elevate the package so it won't evenly solder the
peripheral pads.
We do not do RoHS nor do we trust no-clean solder flux. Our boards are
all put through a standard water wash process. We don't want any
dentrites (or tin whiskers).
Bob Landman
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.
Sent: Wednesday, August 07, 2013 11:50 AM
To: [log in to unmask]
Subject: Re: [TN] QFN solder voiding
I respect the information in the alternative response. If all of the steps
Dave lists below are followed, the components should be reliable.
But they definitely are more problematic, so if a leaded package is
available, I would choose that over the QFN. While the X-ray image may
show the resultant belly pad SJ quite clearly, it cannot always tell you
that you have full solder wetting on the PWB pad AND the QFN belly pad. A
laminar X-ray may be required. I have seen too many examples of a dome of
solder under the component wetted to the board pad but not to the bottom
of the component. This can happen if the aperture reduction that is
required is too much, or if for whatever reason the solder on the
peripheral pads hold the component up such that the wetting does not occur
on the belly pad, or the amount of paste on the belly pad is too thin due
to a printer set-up issue, or the part reflows with a slight tilt,
or...........
So if there is any variation in the process, the reliability immediately
goes south.
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: Wednesday, August 07, 2013 9:45 AM
To: TechNet E-Mail Forum; Stadem, Richard D.
Subject: Re: [TN] QFN solder voiding
Hi team! Ok, let me provide an alternative response to Richard's position.
We have used QFNs on many avionics products -both commercial and military
- for over 5 years. Using the IPC-9701 specification test protocols, QFNs
with soldered center pads have been demonstrated to be as reliable as BGAs
under -55C to +125C thermal cycling conditions. QFNs do require processing
focus as the solder paste print and reflow profiles are critical to having
acceptable solder joint integrity and process yield success. One of the
critical parameters to having acceptable solder joint integrity is the
soldering of center pad on the QFN packages. The soldered center pad
creates a large solder joint that can offset the CTE mismatch - several
industry studies have shown that QFNs without soldered center pads have
lower solder joint integrity than their counterparts. I recommend you
look at two reference sources: (1) the IPC-7093 standard which covers the
Design and Assembly of Bottom Terminated Components which includes QFNs;
(2) The NASA DoD Lead-free Solder Project did extensive testing covering
thermal cycle, vibration and drop shock with a test vehicle that included
QFNs. The link to those reports is:
http://teerm.nasa.gov/nasa_dodleadfreeelectronics_proj2.htm
Read thru the information and then decide if QFN component technology is
applicable for your product. Good Luck.
Dave Hillman
Rockwell Collins
[log in to unmask]<mailto:[log in to unmask]>
From: "Stadem, Richard D." <[log in to unmask]<
mailto:[log in to unmask]>>
To: <[log in to unmask]<mailto:[log in to unmask]>>
Date: 08/07/2013 07:13 AM
Subject: Re: [TN] QFN solder voiding
Sent by: TechNet <[log in to unmask]<mailto:[log in to unmask]>>
________________________________
We do not use QFNs if at all possible. Their reliability issues are very
well known and well-documented. Their use is discouraged in the military
electronics/high rel industry.
And before all of you folks out there tell me "oh, we use them all the
time, but you have to know how", well, we know how, but why bother?
As an industry consultant outside of GD, I have been involved in countless
numbers of calls for QFN issues. I know how to set up a reliable assembly
process for them, but again, why bother with all of that extra cost?
Bottom line is that there is a reduced reliability inherent with using a
package that has radically different CTE than the substrate it is soldered
to, they have no compliant leads to absorb some of the CTE mismatch, the
wetting characteristics are difficult to balance across all of the
peripheral pads, and voiding is almost always an issue.
With stand-off mitigations, the issues are much improved, but only at
extra cost and it requires two stage processing.
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kerr, Bryan (UK)
Sent: Wednesday, August 07, 2013 6:53 AM
To: [log in to unmask]<mailto:[log in to unmask]>
Subject: Re: [TN] QFN solder voiding
Hi Wayne
Interesting. We are using the same kind of materials to process and
unfortunately have many more than one to fit so hand tin is not an option.
Previous work by myself has shown that extending time above liquidus makes
no real difference to voiding levels. For high rel processes using mildly
active fluxes it may be that commercial QFN's with tin finishes are simply
not compatible if voids are to be minimised ? As you say, stronger water
based fluxes would give you a different result I'm sure - opens up the
process window but not an option for some.
Anyone any thoughts on how much voiding on a peripheral pad would be an
issue ? Any thoughts on QFN reliability in general (with or without stand
off mitigations !)
Regards
Bryan
-----Original Message-----
From: Wayne Thayer [mailto:[log in to unmask]]
Sent: 07 August 2013 12:45
To: TechNet E-Mail Forum; Kerr, Bryan (UK)
Subject: RE: QFN solder voiding
----------------------! WARNING ! ---------------------- This message
originates from outside our organisation, either from an external partner
or from the internet.
Keep this in mind if you answer this message.
Follow the 'Report Suspicious Emails' link on IT matters for instructions
on reporting suspicious email messages.
--------------------------------------------------------
Hi Bryan-
I've had problems with those. I think the main problem is stripping the
tin oxide. I speculated that perhaps because I was using Rosin flux and
Pb based soldering temperatures, it didn't strip that oxide as well or
quickly as higher temperatures with more highly active aqueous fluxes. Try
extending the time above liquidus.
On the other hand, if you only have to make one, you can hand tin, or even
bump, the pads on the QFN, and then reflow. For me, that has always led
to the most void-free joints on these parts.
Wayne Thayer
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kerr, Bryan (UK)
Sent: Wednesday, August 07, 2013 7:38 AM
To: [log in to unmask]<mailto:[log in to unmask]>
Subject: [TN] QFN solder voiding
Hi Folks
I am familiar with most of the industry thoughts and standards on voiding
in the centre paddle of QFN's but has anyone any experience with voiding
in the peripheral pads ? From my experience this can vary fairly widely
and there are no standards that I know of which would cover this - unless
anyone can enlighten me ?
Bryan Kerr
Principal Quality Engineer
CMA Lab and Process Engineering
BAE Systems Maritime Services
Manufacturing Hillend
Hillend Industrial Estate
Hillend
Nr Dunfermline
Fife
Scotland
KY11 9HQ
01383-836097
********************************************************************
This email and any attachments are confidential to the intended recipient
and may also be privileged. If you are not the intended recipient please
delete it from your system and notify the sender.
You should not copy it or use it for any purpose nor disclose or
distribute its contents to any other person.
********************************************************************
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]<
mailto:[log in to unmask]>
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]<
mailto:[log in to unmask]>
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]<
mailto:[log in to unmask]>
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|