Hi Joyce,

Thanks for reply

Lyon Yuan


-----Original Message-----
From: Joyce Koo [mailto:[log in to unmask]] 
Sent: Monday, July 15, 2013 10:24 PM
To: 'TechNet E-Mail Forum'; 'Lyon Yuan'
Subject: RE: [TN] What are all the probable causes of non-wetting for OSP
board test pads when the circuit boards are run through our reflow

Oxidation. 

Joyce Koo
Researcher
Materials Interconnect Lab
Office: (519) 888-7465 79945
BlackBerry: (226) 220-4760

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Lyon Yuan
Sent: Monday, July 15, 2013 10:15 AM
To: [log in to unmask]
Subject: Re: [TN] What are all the probable causes of non-wetting for OSP
board test pads when the circuit boards are run through our reflow

Hi Victor,

I apply some flux on non-wetting test pads and reflow again. The solder is
good. It made me confused.

Lyon Yuan

-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]] On Behalf Of
Victor Hernandez
Sent: Monday, July 15, 2013 10:01 PM
To: [log in to unmask]
Subject: Re: [TN] What are all the probable causes of non-wetting for OSP
board test pads when the circuit boards are run through our reflow

Contaminate by solder mask process?
Thickness of OSP?

Victor,

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Brian Ellis
Sent: Monday, July 15, 2013 8:35 AM
To: [log in to unmask]
Subject: Re: [TN] What are all the probable causes of non-wetting for OSP
board test pads when the circuit boards are run through our reflow

In order, the most probable first:
- the underlying copper has not been correctly cleaned before applying the
OSP
- the underlying copper has been brushed, pumiced or otherwise treated with
an abrasive
- the underlying copper, if electrolytic, has been deposited from a badly
controlled/filtered solution, causing co-deposits of organic additives or
simply particulate contamination
- your OSP has passed its sell-by date

Brian

On 15.07.2013 14:19, Lyon Yuan wrote:
> Hi All,

> What are all the probable causes of non-wetting for OSP board test 
> pads when the circuit boards are run through reflow?
>
> Lyon Yuan
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or 
> [log in to unmask] 
> ______________________________________________________________________
>

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential
information, privileged material (including material protected by the
solicitor-client or other applicable privileges), or constitute non-public
information. Any use of this information by anyone other than the intended
recipient is prohibited. If you have received this transmission in error,
please immediately reply to the sender and delete this information from your
system. Use, dissemination, distribution, or reproduction of this
transmission by unintended recipients is not authorized and may be unlawful.



______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2