In order, the most probable first:
- the underlying copper has not been correctly cleaned before applying 
the OSP
- the underlying copper has been brushed, pumiced or otherwise treated 
with an abrasive
- the underlying copper, if electrolytic, has been deposited from a 
badly controlled/filtered solution, causing co-deposits of organic 
additives or simply particulate contamination
- your OSP has passed its sell-by date

Brian

On 15.07.2013 14:19, Lyon Yuan wrote:
> Hi All,
>
>
>
>
>
> What are all the probable causes of non-wetting for OSP board test pads when
> the circuit boards are run through reflow?
>
>
>
>
>
>
>
> Lyon Yuan
>
>
>
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>