Wondering if I can pick the brain of somebody out there.  When performing
Dielectric strength testing most of my failures are the result of a GFI.  I
can turn this feature off on my instrument and was wondering if most people
who do this testing do the same.  I know this is a safety feature but I'm
trying to find a more standardized way of doing this test.  What are the
likely consequences of turning this feature off?  Any advice would be
appreciated.