Suppliers and users of conformal coatings,

I've recently had a request for the Mil-I-46058 Group A test results 
(Group A tests includes Cure Time & Temperature, Appearance, and 
Thickness) to be added to a coatings C of A.  I have a concern that adding 
this information will cause some confusion among those not familiar with 
the Mil-Spec, such as that the Thickness result will somehow be 
interpreted to be a type of qualitative property of the coating. 
The coating is tested to 46058 and is on the QPL.

I have been in the coating industry for 20+ years and in direct support of 
our coatings for the last 10 years.  This is the first request that we've 
had for this information.  Therefore, I am trying to understand if this is 
a unique request or if others in the military community are thinking of 
also adding these results as a Cert requirement.

Suppliers/manufacturers - have you received similar requests for reporting 
the Group A results?

Users - do you have internal requirements to obtain Group A results?  Or, 
do you have future plans for requesting this data?  Are you aware of any 
new requirements that would drive this request?

It seems odd to me to receive a request for this information now, almost 
15 years after the Mil-Spec was declared inactive for new product design. 

Thanks in advance for your input and comments.

Lamar Young
Specialty Coating Systems, Inc.
7645 Woodland Dr.
Indianapolis, IN 46278
(317) 244-1200 Ext. 276
www.scscoatings.com