Hi Victor - just a word of clarification. The IPC-7095 specification is
not a requirements document. A requirement for having a BGA Keep Out Zone
would be in the IPC JSTD 001 if it existed and I don't believe there is
keep out zone criteria in the JSTD-001 specification because of the design
specific nature of such a zone. The IPC-7095 document contains a wealth of
information that you can use to develop a keep out zone requirement but
the specification itself does not contain acceptability criteria. For
example, the IPC-7095 specification contains a ton of information on BGA
voiding but the JSTD-001 contains the acceptability criteria for BGA
voids.
Dave Hillman
Rockwell Collins
[log in to unmask]
From: Victor Hernandez <[log in to unmask]>
To: <[log in to unmask]>
Date: 04/03/2013 06:29 AM
Subject: [TN] IPC-7095, BGA Keep Out Zone, IPC Standard
Sent by: TechNet <[log in to unmask]>
Fellow TechNetters:
According to the above stated IPC Standard, section 6.1.1 Pick and Place
Requirements No special placement and CLEARANCE requirement are needed for
the component pick and place operation."" However, if it does require
corner edge glue for reliability purposes then the edge glue will
encounter some issue/concerns/obstacles. Ceramic components will be
saturated will glue and/or create a conflict with glue height for heat
sink placement.
I did send Steve some photos for viewing.
Victor,
From: Hernandez, Victor G
Sent: Tuesday, April 02, 2013 1:23 PM
To: TechNet E-Mail Forum ([log in to unmask]<mailto:[log in to unmask]>)
Cc: Hernandez, Victor G
Subject: BGA Keep Out Zone, IPC Standard
Fellow TechNetters:
Where within the IPC Standards can I find the above stated guidelines
for components placement on the periphery of a BGA device.?
Victor,
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|