Hi All,

One additional question regarding use of filled/plugged vias. With the plated hole in the pad, how much temperature differential might that induce when the design has inner pads on a BGA with the copper plated hole (vias) and the outer pads don't? I would expect the inner pads to have a lower maximum temperature to begin with due to less exposure to both convection and radiant heat when going through a typical reflow oven. Add to that the conduction into the board by the copper in the via holes and I suspect there will be an additional temperature difference between the solder joints on the outer pads without vias and the inner pads with them. Has anyone determined the magnitude of this effect? 

Thanks,
Bob Furrow
Quality Assurance Engineer
Honeywell Aerospace - Sarasota
941-360-6285
[log in to unmask]  

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of David Bealer
Sent: Tuesday, April 23, 2013 9:17 AM
To: [log in to unmask]
Subject: [TN] Via in pad using filled or plugged vias

We are looking at the possibility of using boards designed with vias in pad and having those vias filled.  What should we be concerned with? ( I know this is a overly broad question, just looking for a place to start.)

Thanks,

David Bealer
SMT Department Manager
office 800-637-2645 x6022   cell 217-474-8760
email [log in to unmask]<mailto:[log in to unmask]>

Watchfire Headquarters  *  watchfiresigns.com<http://www.watchfiresigns.com/>
sales 800-637-2645   service 866-637-2645


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2