TECHNET Archives

April 2013

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Vladimir Igoshev <[log in to unmask]>
Reply To:
Date:
Wed, 17 Apr 2013 22:46:57 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (31 lines)
Techneters,

I have another tricky question.

We see separation at the Cu pad/laminate interface. The area is rather small (20 microns in section), BUT it's located at the periphery of BGA pads.

My concern is that the separation will act as a stress concentrator causing pad cratering, once the BGA is placed. 

I'm positive it's a real scenario, as we investigated a similar case over a year ago.

According to 6012C the board is acceptable (at least from my understanding).

The question is: Is there a way  to legitimately reject the board?


Regards,

Vladimir

SENTEC Testing Laboratory Inc.
11 Canadian Road, Unit 7.
Scarborough, ON M1R 5G1
Tel: (647) 495-8727
Cell: (416) 899-1882
www.sentec.ca

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________