DESIGNERCOUNCIL Archives

April 2013

DesignerCouncil@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Tan Geok Ang <[log in to unmask]>
Reply To:
(Designers Council Forum)
Date:
Sun, 28 Apr 2013 02:56:04 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (103 lines)
Any shock and vibration data with what PCB thickness and PTH plating (should not be ENIG as the video shown doesn't indicate it is gold plated contact mating into the PCB PTH)  thickness requirements?

________________________________________
From: DesignerCouncil [[log in to unmask]] on behalf of Steve Smith [[log in to unmask]]
Sent: Friday, 26 April, 2013 10:19:08 PM
To: [log in to unmask]
Subject: Re: [DC] New 60 amp PCB connector

From their data sheet:

The current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts.
The derating curve is therefore valid for currents which flow constantly (non-intermittent) through each contact element of the connector evenly, without exceeding the
allowed maximum temperature.

Measuring and testing techniques according to
DIN EN 60 512-5


The curve shows three different wire sizes and with 10 mm² wire the current is 60 amps at around 35°C ambient.

My regards,
Steve Smith
Project Engineer
Staco Energy Products Co.
"Your tailored power solutions provider"



DISCLAIMER AND/OR CONFIDENTIALITY NOTICE:
This message, including any attached materials, is intended solely for the use of the individual or entity to whom it is addressed and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. If the reader of this electronic mail transmission is not the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please e-mail or call Staco Energy Products Co. at (937) 253-1191. Thank you for your cooperation.

-----Original Message-----
From: DesignerCouncil [mailto:[log in to unmask]] On Behalf Of Greg Feneis
Sent: Friday, April 26, 2013 10:04 AM
To: [log in to unmask]
Subject: Re: [DC] New 60 amp PCB connector

I'm curious to find out about what was the layout of the test PCB and other conditions of the test that let them rate it to 60A.  Or maybe it's not 60A continuous?





Kind Regards,

Greg Feneis
650-678-4670

Electromechanical <http://www.linkedin.com/in/electromechanical>



On Fri, Apr 26, 2013 at 6:31 AM, James Jackson <[log in to unmask]> wrote:

> Well, _I'M_ impressed.
>
> (of course, it doesn't take much to impress me)
>
> James Jackson
> Oztronics
>
>
> Quoting Steve Smith <[log in to unmask]>:
>
> > An interesting 60 amp PCB connector from Harting:
> >
> > http://www.mouser.com/new/harting/harting-hanfastlock/?
>
> utm_medium=email&utm_source=april2013&utm_campaign=cm-general&utm_cont
> ent=lm2
> >
> > Watch the video to see how it plugs in.  I don't see that it has a
> > UL listing but seems very nice.
> >
> > Regards,
> > Steve Smith

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 16.0.
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 16.0.
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

ATOM RSS1 RSS2