ENIG indeed.

Should I dread the underlying Ni, being stiffer, would reduce the number of cycles? 

Ioan Tempea, ing.
Ingénieur principal de fabrication / Senior Manufacturing Engineer


950 RUE BERGAR, LAVAL, QC, H7L 5A1
T+ 1 (450) 967-7100, EXT244
------------------------------------------------------------------------
  
------------------------------------------------------------------------
Lauréat Dunamis 2012
Entreprise manufacturière / Gestion du capital humain


-----Message d'origine-----
De : [log in to unmask] [mailto:[log in to unmask]] 
Envoyé : March-04-13 9:38 AM
À : [log in to unmask]; Ioan Tempea
Cc : [log in to unmask]
Objet : RE: [TN] Conductive path failure in thermal cycling

Was this an ENIG surface finish?   Over aggressive ENIG preparation process step down.

Victor,

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Ioan Tempea
Sent: Monday, March 04, 2013 8:23 AM
To: [log in to unmask]
Subject: Re: [TN] Conductive path failure in thermal cycling

Thanks Dave,

Completely lost trace of Steve, please check this link http://ipc-technet.groupsite.com/galleries/show/25304

Unfortunately, I only have 1 pic.

Ioan Tempea, ing.
Ingénieur principal de fabrication / Senior Manufacturing Engineer [signature002]<http://www.digico.cc/>

950 RUE BERGAR, LAVAL, QC, H7L 5A1<http://g.co/maps/2gh3f>
T+ 1 (450) 967-7100, EXT244
------------------------------------------------------------------------
  [signature001] <http://www.facebook.com/pages/Digico/277076778479>
------------------------------------------------------------------------
Lauréat Dunamis 2012<http://digico.cc/dunamis-2012/>
Entreprise manufacturière / Gestion du capital humain

De : [log in to unmask] [mailto:[log in to unmask]]
Envoyé : March-04-13 9:09 AM
À : TechNet E-Mail Forum; Ioan Tempea
Objet : Re: [TN] Conductive path failure in thermal cycling

Hi Ioan - I have recently ran into an plating process issue with immersion silver - the term being used to describe the anomaly is "trench etch".  This defect is made worst by lead-free soldering processes where copper dissolution comes into play. Your defect sounds like it could be "trench etch" but you have ENIG and not immersion silver. Please send Steve a couple of pictures of your defect and we'll try to sleuth out the root cause.

Dave



From:        Ioan Tempea <[log in to unmask]<mailto:[log in to unmask]>>
To:        <[log in to unmask]<mailto:[log in to unmask]>>
Date:        03/01/2013 03:08 PM
Subject:        Re: [TN] Conductive path failure in thermal cycling
Sent by:        TechNet <[log in to unmask]<mailto:[log in to unmask]>>
________________________________



ENIG

Ioan Tempea, ing.
Ingénieur principal de fabrication / Senior Manufacturing Engineer [signature002]<http://www.digico.cc/>

950 RUE BERGAR, LAVAL, QC, H7L 5A1<http://g.co/maps/2gh3f>
T+ 1 (450) 967-7100, EXT244
------------------------------------------------------------------------
 [signature001] <http://www.facebook.com/pages/Digico/277076778479>
------------------------------------------------------------------------
Lauréat Dunamis 2012<http://digico.cc/dunamis-2012/>
Entreprise manufacturière / Gestion du capital humain

De : [log in to unmask]<mailto:[log in to unmask]> [mailto:[log in to unmask]]
Envoyé : March-01-13 2:30 PM
À : TechNet E-Mail Forum; Ioan Tempea
Objet : Re: [TN] Conductive path failure in thermal cycling

Hi Ioan - what is the assembly surface finish?

Dave Hillman
Rockwell Collins
[log in to unmask]<mailto:[log in to unmask]>



From:        Ioan Tempea <[log in to unmask]<mailto:[log in to unmask]>>
To:        <[log in to unmask]<mailto:[log in to unmask]>>
Date:        03/01/2013 10:40 AM
Subject:        [TN] Conductive path failure in thermal cycling
Sent by:        TechNet <[log in to unmask]<mailto:[log in to unmask]>>
________________________________



Dear Technos,

RoHS assembly, soldered with SAC305 alloy, 0.075" thick 14 layers PCB, failing after 250 cycles (-20 C to 125 C).

Failure mode is crack between the traces and pad at 3 places. Happens on 2 TH components. Traces are 0.0055" wide, pads are 0.022" in diameter on the via side or 0.065" on the component side. There is no tear dropping.

Should I bother figuring out if manual soldering of the TH component fragilizes the trace-pad junction, or this is an obvious case of design induced failure?

Thanks,

Ioan Tempea, ing.
Ingénieur principal de fabrication / Senior Manufacturing Engineer [signature002]<http://www.digico.cc/>

950 RUE BERGAR, LAVAL, QC, H7L 5A1<http://g.co/maps/2gh3f>
T+ 1 (450) 967-7100, EXT244
------------------------------------------------------------------------
[signature001] <http://www.facebook.com/pages/Digico/277076778479>
------------------------------------------------------------------------
Lauréat Dunamis 2012<http://digico.cc/dunamis-2012/>
Entreprise manufacturière / Gestion du capital humain


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]<mailto:[log in to unmask]>
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]<mailto:[log in to unmask]>
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2