TECHNET Archives

March 2013

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, [log in to unmask]
Date:
Thu, 14 Mar 2013 11:05:44 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (99 lines)
Victor,

IPC-6012 is not good at 

 

 

 

-----Original Message-----
From: Victor Hernandez <[log in to unmask]>
To: TechNet <[log in to unmask]>
Sent: Thu, Mar 14, 2013 5:44 am
Subject: Re: [TN] IPC-6012


Can someone quote chapter and verse if this is a rejectable anomaly.   In 
IPC-A-600F, "Non-Conforming - Class 1, 2, & 3   No lift allowed from the 
laminate plane to the bottom surface at the end of the copper land, whether or 
not resin appears on the copper land off the board."   Need judgment from the 
gurus as what that really mean and with photos to ensure the issue is well 
understood.

Victor,

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Paul Reid
Sent: Thursday, March 14, 2013 7:25 AM
To: [log in to unmask]
Subject: Re: [TN] IPC-6012

Hi Vladimir,
 
What you have here is a lifted pad. I think that that is rejectable to 6012. 
 
There appears to be an adiquate wrap of copper.
 
Best regards,
 
Paul Reid

________________________________

From: TechNet on behalf of Vladimir Igoshev. PhD
Sent: Wed 13/03/2013 5:18 PM
To: [log in to unmask]
Subject: [TN] IPC-6012



I have a question for boards gurus,

We run a set of tests to assess the workmanship of a PWB. The board had 
vias-in-pad (in essence PTHs overplated with Cu pads) under a BGA.

After a thermal stress the pads were partially flitted due to cracked laminated 
underneath them. To me it's a recipe for disaster  (like pad
cratering after assembly).     However, I saw nothing about it in
IPC-6012. Did I just miss it?

I'd really appreciate any contractive comments.

--
Best regards,

Vladimir Igoshev. PhD                          mailto:[log in to unmask]

SENTEC Testing Laboratory Inc.
11 Canadian Road, Unit 7.
Scarborough, ON M1R 5G1
Tel: (416) 899-1882
Fax: (905) 882-8812
www.sentec.ca

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________



______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

 

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2