My bane was must coat and must not coat with no transition area.
This was for automated dispensing.
Even with masking to give a sharp edge, there is a tolerance on the
location.
Something should be noted as to need for a tolerance or a don't care area
between the 2, even if it is up to the individual design to specify it.
A paralyene contractor told me he could hold 4 mils. That is not zero and I
hate to think of the price to hold that tolerance.
For the 100 panel/ an hour shops, it has to be larger.