TECHNET Archives

January 2013

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Ramakrishnan Saravanan <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Ramakrishnan Saravanan <[log in to unmask]>
Date:
Tue, 1 Jan 2013 08:36:41 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (26 lines)
Dear Mr Paul, 

What is the correct make up of micro-etch solution. We use the following make up

1. 15ml of liquid ammonia 
2. 4 ml of Hydrogen Peroxide 
3. 25 ml of DI water. 


Our humidity levels are 95%. The problem is some times good results are obtained after half an hour after the makeup. 

sometimes after 45 minutes and sometimes after one hour. 

After preparation what is the optimum time required to use the solution.  After preparing whether we have to keep the solution in closed or open condition ?. Whether make is correct ?. We dip the mould in the solution .

We are using hot mount techniques for pcb micro-section. Phenolic power is used as epoxy. Kindly advise regards,

R.Saravanan
 





 

ATOM RSS1 RSS2