Thank you Sir.  The 5-32c group put a lot into that document, but we have 
not yet released that document.  We have one remaining issue, related to 
ROSE testing, that we have yet to resolve.  I hope to have that all 
cleared away by Apex.  Don't want to bring out the Imperial Light Saber if 
I don't have to.

Doug Pauls



From:   "Stadem, Richard D." <[log in to unmask]>
To:     <[log in to unmask]>
Date:   01/09/2013 12:31 PM
Subject:        Re: [TN] TM 650 , Method 2.6.3.5 - Bare Board SIR
Sent by:        TechNet <[log in to unmask]>



I don't know who the members are of the team who wrote IPC-5703, but I 
must certainly say that is one of the best most informative documents I 
have seen the IPC put out. That committee should be commended for an 
excellent job.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.
Sent: Wednesday, January 09, 2013 11:59 AM
To: [log in to unmask]
Subject: Re: [TN] TM 650 , Method 2.6.3.5 - Bare Board SIR

IPC-5703 and 5704 should also be added. WP-008 should also be referenced.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Whittaker, Dewey 
(EHCOE)
Sent: Wednesday, January 09, 2013 11:49 AM
To: [log in to unmask]
Subject: Re: [TN] TM 650 , Method 2.6.3.5 - Bare Board SIR

Well SIR, so much for a clean getaway.
I have tried to get Method 2.6.3.5 added to IPC-6012 for awhile. We have 
had to add it as a required test for pre SMOBC application and a post HASL 
process, as well as the applicable cleanliness requirements/tests.
Dewey

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Graham Naisbitt
Sent: Wednesday, January 09, 2013 10:39 AM
To: [log in to unmask]
Subject: Re: [TN] TM 650 , Method 2.6.3.5 - Bare Board SIR

Happy New Year everyone, WOW that got some attention!

I certainly recall the debate when we finalised 2.6.3.7 so....I went have 
a look at my files and: Sorry I am wrong! 

When I checked all my files I evidently picked-up on the wrong document. 
It was in 2.6.3.6 wherein we have:

"This method, in conjunction with the supporting documentation in 
IPC-J-STD-004, is intended to be equivalent to Telcordia Technologies 
GR-78-CORE, Section 13.1..." (We tried to insert "Superseded" but it 
wasn't accepted.

I do however stand by my question of whether IPC 6012 will be reviewed - 
it is due and this would be a useful catch-up?

Graham


On 9 Jan 2013, at 16:06, Douglas Pauls <[log in to unmask]> 
wrote:

> Method 2.6.3.5 was a shameless copying of the SIR testing for bare 
> board fabricators, required in Bellcore GR-78-CORE, as Graham 
> indicated.  At the time we drafted 2.6.3.5, Bellcore was devoting no 
> technical resources to that document and was not supporting it, so IPC 
put the method in place.
> 
> Graham, are you certain the SIR test in GR-78-CORE was superceded by 
> 2.6.3.7?  I know the J-STD-004 flux requirements went that way, but 
> this would be the first that I had heard that Bellcore likewise 
> adopted it.  I agree that the GR-78-CORE test is quite old, but it was 
> still a pretty good test to determine cleanliness.  The almost 
> impossibly high levels were very difficult to achieve if you had any 
> detrimental residues present.
> 
> Doug Pauls
> 
> 
> 
> From:   Graham Naisbitt <[log in to unmask]>
> To:     <[log in to unmask]>
> Date:   01/09/2013 09:56 AM
> Subject:        Re: [TN] TM 650 , Method 2.6.3.5 - Bare Board SIR
> Sent by:        TechNet <[log in to unmask]>
> 
> 
> 
> Hi Richard
> 
> To the best of my knowledge that was called up by IPC 6012. I don't 
> know whether this is under review - but it should be (2007 = 5 year 
> rule). I will take this matter up with the group at APEX.
> 
> I suggest you apply some caution to the veracity of any data you 
> produce, as the method really needs to be updated. The old Bellcore 
> GR-78-CORE was superceded by method 2.6.3.7
> 
> Hope this helps
> 
> Graham Naisbitt ? Vice-Chairman IPC TGs: SIR / ECM; CAF & 7-11 Test 
> methods Sub-Committee, IEC TC91 WG3 Project Leader, BSi EPL 501, UK 
> IAG
> E: [log in to unmask]
> T: 012 5252 1500
> 
> 
> 
> On 7 Jan 2013, at 20:29, Richard Kraszewski 
> <[log in to unmask]> wrote:
> 
>> Can anyone tell me which IPC bare board documents references test 
>> method
> 2.6.3.5 to meet a minimum SIR requirement?
>> 
>> Rich  Kraszewski - Plexus Engineering
>> 
>> 
>> _____________________________________________________________________
>> _ This email has been scanned by the Symantec Email Security.cloud
> service.
>> For more information please contact helpdesk at x2960 or
> [log in to unmask]
>> _____________________________________________________________________
>> _
> 
> 
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud 
service.
> For more information please contact helpdesk at x2960 or 
> [log in to unmask] 
> ______________________________________________________________________
> 
> 
> 
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud 
service.
> For more information please contact helpdesk at x2960 or 
> [log in to unmask] 
> ______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2