Well, keep in mind you are talking about two different SIR methods for two 
different purposes.

Method 2.6.3.7 is the most modern method for testing the effects of flux 
residues, which is why it is used for J-STD-004.

Method 2.6.3.5, a copy of the Bellcore method, was designed to test the 
cleanliness of board layers prior to lamination, not flux effects.

Doug Pauls



From:   "MacFadden, Todd" <[log in to unmask]>
To:     <[log in to unmask]>
Date:   01/09/2013 11:09 AM
Subject:        Re: [TN] TM 650 , Method 2.6.3.5 - Bare Board SIR
Sent by:        TechNet <[log in to unmask]>



Likewise, IPC-9201A (2007), the Surface Insulation Handbook references 
Method 2.6.3.7, but not 2.6.3.5.

Todd


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Whittaker, Dewey 
(EHCOE)
Sent: Wednesday, January 09, 2013 11:29 AM
To: [log in to unmask]
Subject: Re: [TN] TM 650 , Method 2.6.3.5 - Bare Board SIR

Revision C (2010) of IPC-6012 has IPC-TM-650, Method 2.6.3.7 as an 
applicable document, but not Method 2.6.3.5. Also I could find no 
reference to a supersedure notice. I could not find Method 2.6.3.5 listed 
anywhere I would have expected it to be.
Dewey 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Graham Naisbitt
Sent: Wednesday, January 09, 2013 8:49 AM
To: [log in to unmask]
Subject: Re: [TN] TM 650 , Method 2.6.3.5 - Bare Board SIR

Hi Richard

To the best of my knowledge that was called up by IPC 6012. I don't know 
whether this is under review - but it should be (2007 = 5 year rule). I 
will take this matter up with the group at APEX.

I suggest you apply some caution to the veracity of any data you produce, 
as the method really needs to be updated. The old Bellcore GR-78-CORE was 
superceded by method 2.6.3.7

Hope this helps

Graham Naisbitt - Vice-Chairman IPC TGs: SIR / ECM; CAF & 7-11 Test 
methods Sub-Committee, IEC TC91 WG3 Project Leader, BSi EPL 501, UK IAG
E: [log in to unmask]
T: 012 5252 1500



On 7 Jan 2013, at 20:29, Richard Kraszewski 
<[log in to unmask]> wrote:

> Can anyone tell me which IPC bare board documents references test method 
2.6.3.5 to meet a minimum SIR requirement?
> 
> Rich  Kraszewski - Plexus Engineering
> 
> 
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud 
service.
> For more information please contact helpdesk at x2960 or 
> [log in to unmask] 
> ______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2