Graham,
Are you certain??? When did method 2.6.3.7 supercede the GR-78-CORE
document? I had not heard this information, but I may have been left out
of that loop.
Regards,
Joe Russeau
----- Original Message -----
From: "Graham Naisbitt" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, January 09, 2013 10:48 AM
Subject: Re: [TN] TM 650 , Method 2.6.3.5 - Bare Board SIR
> Hi Richard
>
> To the best of my knowledge that was called up by IPC 6012. I don't know
> whether this is under review - but it should be (2007 = 5 year rule). I
> will take this matter up with the group at APEX.
>
> I suggest you apply some caution to the veracity of any data you produce,
> as the method really needs to be updated. The old Bellcore GR-78-CORE was
> superceded by method 2.6.3.7
>
> Hope this helps
>
> Graham Naisbitt – Vice-Chairman IPC TGs: SIR / ECM; CAF & 7-11 Test
> methods Sub-Committee, IEC TC91 WG3 Project Leader, BSi EPL 501, UK IAG
> E: [log in to unmask]
> T: 012 5252 1500
>
>
>
> On 7 Jan 2013, at 20:29, Richard Kraszewski
> <[log in to unmask]> wrote:
>
>> Can anyone tell me which IPC bare board documents references test method
>> 2.6.3.5 to meet a minimum SIR requirement?
>>
>> Rich Kraszewski - Plexus Engineering
>>
>>
>> ______________________________________________________________________
>> This email has been scanned by the Symantec Email Security.cloud service.
>> For more information please contact helpdesk at x2960 or [log in to unmask]
>> ______________________________________________________________________
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]