Hi,
It seems, the via holes also have metal residues,
[image: Inline image 1]
On Wed, Dec 5, 2012 at 6:49 PM, Steve Gregory <
[log in to unmask]> wrote:
> Hi Mordechai,
>
> I have not seen anything like this before. I’ve posted your pictures so
> everyone else can see:
>
> http://stevezeva.homestead.com/Pad_Wrinkle.jpg
>
> http://stevezeva.homestead.com/Via_Xsection.jpg
>
> Could you share what the overall stack-up of this board was supposed to be
> and what prepreg thickness was used?
>
> Steve
>
> From: Mordechai Kirshenbaum
> Sent: Tuesday, December 04, 2012 3:16 PM
> To: [log in to unmask]
> Subject: A PCB defect that is not specified by IPC
>
>
> Hi Steve
>
> On routine visual inspection of an income PCB board we found a type of the
> defect
> that is not specified in any of the IPC standards (e.g IPC-A-600
> Acceptability of Printed Boards).
>
> It looks like wrinkles on pads and conductors (see fig 1 in the
> attached file). We suspected that it was caused
> by thick copper conductor on the second layer (under the outer layer).
>
> We measured the copper and the dielectric thickness between the outer and
> the second layers
> and found that the copper thickness on the 2nd layer was relatively high
> (70 micro-meter), and the
> dielectric thickness lower than specified (only 50 microns).
>
> Have you seen similar defect?
> What is the reliability impact?
> Is it acceptable for class 3?
>
> Best regards
> Mordechai Kirshenbaum
> MOD, Israel
>
> P.S. please feel free to post this question on the technet forum.
>
>
>
>
>
>
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
--
Best Regards,
*Reuven Rokah*
Mobile: 972-52-6012018
Tel: 972-3-9360688
Fax: 076-5100674
<http://www.rokah-technologies.com/>[log in to unmask]
[log in to unmask]
www.rokah-technologies.com
**
This e-mail message is intended for the recipient only and contains
information which is CONFIDENTIAL and which may be proprietary of Rokah
Technologies. If you have received this transmission in error, please
inform me by e-mail, phone or fax, and then please delete all of the
original files and all other copies exist.
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|