Keith, attached is the letter to the one customer, General Dynamics,  who was determined to have received PWBs mistakenly certified to MIL-PRF-55110 as a consequence of microsections having been incorrectly prepared. The incorrect microsections were found during audit VQE-11-022451.

This letter went to General Dynamics supplier quality assurance today, 4 October 2012.

I hope the letter is concise and clear, with no explanation required.  However, if you have any questions, please contact me.

For their information, I am copying Compunetics' Technical Review Board and your colleague Lowell Sherman.

Louis Hart
Compunetics
Monroeville, PA
USA
[log in to unmask]<mailto:[log in to unmask]>
412-858-1232