Gonul
As Brian Ellis said, the static method works best.
I am going to send you a copy of a paper I am giving on this subject at the IPC / SMTA Cleaning & Coating Conference in Chicago in a couple of weeks time.
Graham Naisbitt
On 31 Oct 2012, at 10:09, Gönül Özden <[log in to unmask]> wrote:
> Hello,
>
> I need to know which method in ionic contamination measurement will be more reliable and convenient for military application static process or dynamic process. IPC-TM-650 accept both metodologies.
> Can someone of you have an experience on this issue?
>
> Regards
>
> Gonul Ozden
>
>
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________