once more with feeling....


Cross section.



At 01:36 PM 9/19/2012, Joyce Koo wrote:
>May be your "small expensive friends" should do a thermal shock 5 or 
>10 times prior to assembly to eliminate the problem at PWB 
>level.  (fly probe before and after).
>Good old days, all the high end stuff are pre-screened at batch 
>level prior to assemble and "burn-in" thermal shock 10 times prior 
>to ship to root out any early failure = usually at developing stage, 
>not MFG stage).  Exactly try to avoid expensive mistake later, (was 
>replaced later by a coupon on pwb with (1) finest feature (2) 
>weakest location (3) new features and (4) testable electrically at 
>functional level somewhat, not cheap, but cheaper than risk at 
>assembly level).  Follow the rule of "pay me now and pay me less, or 
>Pay me later and pay me more - usually 10X, if not 100X<  more with 
>debug FA add on and time loss on delivery.
>
>Joyce Koo
>Materials Researcher - Materials Interconnect Lab
>Research In Motion Limited
>Office: (519) 888-7465 79945
>Mobile: (226) 220-4760
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Robert Kondner
>Sent: Wednesday, September 19, 2012 3:41 PM
>To: [log in to unmask]
>Subject: Re: [TN] Broken Vias
>
>Amol,
>
>  Good Questions, I will find out.
>
>Thanks,
>Bob K.
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Amol Kane
>(Asteelflash,US)
>Sent: Wednesday, September 19, 2012 3:30 PM
>To: [log in to unmask]
>Subject: Re: [TN] Broken Vias
>
>Were the boards moisture baked before assembly? .....is the stackup
>balanced? Is the via damage more pronounced in the area of warpage?
>
>
>Amol Kane
>Process Engineer
>AsteelFlash US East Corp
>Tel:   (607) 687.7669 x349 (O)
>www.asteelflash.com
>
>
>ITAR Confidentiality Notice: This e-mail and any attachments are
>confidential. It is intended for the recipient only. Prior to forwarding
>this e-mail or opening any attachments please note that they may contain
>security sensitive, proprietary, or export restricted information. Any
>unauthorized disclosure, use, dissemination, or copying is strictly
>prohibited and may be unlawful. Furthermore, this communication may contain
>technical information that is subject to U.S. Export Control Laws, including
>the International Traffic in Arms Regulations (ITAR) or the Dept. of
>Commerce Export Administration Regulation (EAR). If so, transfer to a
>foreign national or representative of a foreign government or interest, even
>in the U.S., without prior Government authorization is prohibited and
>violation of such Export Control Laws is subject to significant penalties.
>If you received this e-mail in error, please immediately notify the sender
>by replying to this e-mail and delete the e-mail and all copies from your
>computer. Although the sender and Asteelflash have taken every reasonable
>precaution, the e-mail and attachments may have some errors or omissions and
>may contain viruses. We cannot accept liability for any damage that you
>sustain as a result of that
>
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Robert Kondner
>Sent: Friday, September 14, 2012 5:02 PM
>To: [log in to unmask]
>Subject: Re: [TN] Broken Vias
>
>Hi,
>
>  Does anyone know about the TCE of via plug material? I am trying to get a
>material number of what was used. This was the first board we ever ran with
>via plugging but I would think that is a well-known process?
>
>Bob K.
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Jason Zhao
>Sent: Friday, September 14, 2012 12:52 PM
>To: [log in to unmask]
>Subject: Re: [TN] Broken Vias
>
>Bob,
>
>Xsection will show you where the opens occur. Possibilities are: copper
>plating folds; thin copper; corner crack; post separation; separation due to
>no wraparound; etc. Then we can determine the root causes from there (there
>are too many to guess now). Looking forward to some pictures.
>
>Best Regards
>
>Jason Zhao
>VP of North America Operations
>Sunshine Circuits
>3400 Silverstone Drive, Suite 139, Plano, TX 75023 US Cell 510-468-4412,
>China Cell 131-62722392 www.sunshinepcbgroup.com
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Robert Kondner
>Sent: Friday, September 14, 2012 10:18 AM
>To: [log in to unmask]
>Subject: [TN] Broken Vias
>
>Hi,
>
>
>
>A small company in the area has a board with two very expensive parts, about
>$3K each part. They built 30 boards and had lots of open via connections.
>They are getting cross sections now on some bad vias. In addition to many
>bad vias there was some board warp. Sorry I don't have any hard numbers on
>bad via counts or warp.
>
>
>
>These were 10 mil holes in .062 material, a 6:1 aspect ratio, should be
>easy. Vias were plugged and plated so they could be used as flying probe
>test points.
>
>
>
>After reflow assembly the boards were run on a wave machine using a mask
>where about 25% of the board was exposed to the wave. Everything lead free.
>
>
>
>Question:
>
>
>
>Can folks suggest lists of items we can check, measure or inquire into? Any
>guesses or ideas as what might be going on?
>
>
>
>Thanks,
>
>Bob K.
>
>
>
>______________________________________________________________________
>This email has been scanned by the Symantec Email Security.cloud service.
>For more information please contact helpdesk at x2960 or [log in to unmask]
>______________________________________________________________________
>
>
>______________________________________________________________________
>This email has been scanned by the Symantec Email Security.cloud service.
>For more information please contact helpdesk at x2960 or [log in to unmask]
>______________________________________________________________________
>
>
>______________________________________________________________________
>This email has been scanned by the Symantec Email Security.cloud service.
>For more information please contact helpdesk at x2960 or [log in to unmask]
>______________________________________________________________________
>
>______________________________________________________________________
>This email has been scanned by the Symantec Email Security.cloud service.
>For more information please contact helpdesk at x2960 or [log in to unmask]
>______________________________________________________________________
>
>
>______________________________________________________________________
>This email has been scanned by the Symantec Email Security.cloud service.
>For more information please contact helpdesk at x2960 or [log in to unmask]
>______________________________________________________________________
>
>---------------------------------------------------------------------
>This transmission (including any attachments) may contain 
>confidential information, privileged material (including material 
>protected by the solicitor-client or other applicable privileges), 
>or constitute non-public information. Any use of this information by 
>anyone other than the intended recipient is prohibited. If you have 
>received this transmission in error, please immediately reply to the 
>sender and delete this information from your system. Use, 
>dissemination, distribution, or reproduction of this transmission by 
>unintended recipients is not authorized and may be unlawful.
>
>______________________________________________________________________
>This email has been scanned by the Symantec Email Security.cloud service.
>For more information please contact helpdesk at x2960 or [log in to unmask]
>______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2