start with x-section to see what basic failure mode is and look for
latent mfg defects first.
At 10:02 AM 9/17/2012, Julie Silk wrote:
>Where's Paul Reid? He made a comment in a seminar that he sees a
>higher failure rate for filled/plated over vias than for open
>ones. I agree that your exact fill material and characteristics are
>needed. While this process is well-known, the fill and the wrap are
>significant variables. Good selection for the fill, good process
>control for the wrap. And look at what heat has been applied. Any
>rework? For these parts or nearby?
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]