TECHNET Archives

September 2012

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Joyce Koo <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Joyce Koo <[log in to unmask]>
Date:
Fri, 28 Sep 2012 17:37:50 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (90 lines)
Better have NO exposed Nickel: 
http://www.webmd.com/allergies/nickel-jewelry-allergy

Joyce Koo
Materials Researcher - Materials Interconnect Lab
Research In Motion Limited
Office: (519) 888-7465 79945
Mobile: (226) 220-4760


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Victor Hernandez
Sent: Friday, September 28, 2012 1:33 PM
To: [log in to unmask]
Subject: Re: [TN] soldering stainless steel

Perhaps a nickel under plate?

Victor,

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of McGrath, Jim
Sent: Friday, September 28, 2012 12:00 PM
To: [log in to unmask]
Subject: Re: [TN] soldering stainless steel

Preplate the solder area with Sn or SnPb. You may need a copper underplate. 


Jim McGrath
Strategic Marketing Manager
TE Consumer Devices
Cell: 630-244-3872
Email: [log in to unmask]

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Torsten Hagge
Sent: Friday, September 28, 2012 10:17 AM
To: [log in to unmask]
Subject: [TN] soldering stainless steel

Hi all,

has anybody experience with soldering stainless steel parts directly on a PCB? What solder process work fine?

Application is a medical sensor with body contacts.

Torsten


Kind regards

KRISTRONICS GmbH
Torsten Hagge
Gewerbegrund 5-9
24955 Harrislee
Telefon +49 (0) 461 7741-624
Telefax +49 (0) 461 7741-642
[log in to unmask]
www.kristronics.de

Meet at electronica 2012, A6, 409

Gerichtsstand Flensburg, Handelsregister: HRB 1433 FL Geschäftsführer Dipl.-Ing. oec. Thormod Ohm Ust-Id-Nr. DE 811182059
Bankverbindung: Deutsche Bank AG Flensburg, Konto-Nr. 4216610, BLZ 21570011
IBAN: DE32 2157 0011 0421 6610 00, BIC: DEUT DE HH 215



______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2