Hi Bob - yes, not have collapse would be a very bad idea. Soldering a 
lead-free BGA in a tin/lead soldering process automatically creates a 
mixed metallurgy situation which can be a solder joint integrity issue 
depending on the product use environment.  The degree of solder joint 
microstructure mixing/uniformity has a direct impact on the solder joint 
integrity. The customer's suggestion of not having solderball collapse 
would result in the tin/lead solder paste and the lead-free solderball 
being very distinct zones in the final solder joint which would be a worst 
case scenario.

Dave Hillman
Rockwell Collins
[log in to unmask]




Robert Kondner <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]>
09/25/2012 07:26 PM
Please respond to
<[log in to unmask]>


To
<[log in to unmask]>
cc

Subject
[TN] Leaded Paste and Lead Free BGAs - Do they mix?






Hi,

 

I have a customer using leaded paste with lead free BGAs. I think they 
want
to have the balls NOT collapse for better optical inspection.

 

Sounds like a really bad idea to me but I have no explanation where I can
say as why.

 

Can anyone make suggestions either way?

 

Thanks,

Bob K.



______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________



______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2