TECHNET Archives

August 2012

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Gervascio, Thomas L" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Gervascio, Thomas L
Date:
Wed, 29 Aug 2012 14:30:02 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (25 lines)
I have seen that in the past but mainly with 1B31 applied with a select coat system. In that case we changed out the tubing- it turns out that the tubing would allow for diffusion through the plastic tubing. I think the moisture absorption might occur in the spray lines. Might want to take a look at that or try spraying with nitrogen than air.

Tom

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Blair Hogg
Sent: Wednesday, August 29, 2012 10:04 AM
To: [log in to unmask]
Subject: EXTERNAL: [TN] Cloudy Conformal Coating

I'm hoping that Technetters can share some light on an issue that we occasionally experience here - we coat some of our boards with 1B73 conformal coating, for some we have a spary machine, others a sprayed by hand. 

Every so often we will process some board through coating and they will have a cloudy / milky appearance in the coating. We have been told previously that this happens when humidity is up, since our manual spray coating area is not in an air-conditioned environment. 

Anyone else ever have this problem? How did you fix it? 

Thanks,

Blair

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________