Subject: | |
From: | |
Reply To: | |
Date: | Wed, 29 Aug 2012 09:47:20 -0700 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Check to see if you have excessive moisture in the CDA line going to the spray head...
Paul
Paul Edwards
Process/Quality Engineering
Surface Art Engineering
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Blair Hogg
Sent: Wednesday, August 29, 2012 7:04 AM
To: [log in to unmask]
Subject: [TN] Cloudy Conformal Coating
I'm hoping that Technetters can share some light on an issue that we occasionally experience here - we coat some of our boards with 1B73 conformal coating, for some we have a spary machine, others a sprayed by hand.
Every so often we will process some board through coating and they will have a cloudy / milky appearance in the coating. We have been told previously that this happens when humidity is up, since our manual spray coating area is not in an air-conditioned environment.
Anyone else ever have this problem? How did you fix it?
Thanks,
Blair