Subject: | |
From: | |
Reply To: | |
Date: | Wed, 20 Jun 2012 15:52:14 +0000 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Ok, got my specifications, looking at IPC-2221A Figure 10-3, for conductor width (see section 10.1.1 also, pages 77&79); and IPC-A-600H 3.2.1 (see page 86). It looks like "etch factor" drives how much of a trapezoid one has on any given trace, although outer layers (since they are plated) may have overhang.
What I don't see is any qualitative numbers: ie, an etch factor of y +/-z is typical for outer layers, vs w for inner layers. Are these numbers variable from vendor to vendor; and have to be called out on any given FAB drawing, since there isn't a generic number to be pointed at?
Shawn Upton, KB1CKT
Test Engineer
Allegro MicroSystems, Inc
[log in to unmask]
603.626.2429/fax: 603.641.5336
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]