Hi Phil,

You mean like Tantalum capacitors? I just went back and double checked the
gerbers for the board that I took a photo of earlier today, and the solder
paste apertures are 1-to-1 with the metal layer. 

We also ran the other side of the board that I took the photo of and I
couldn't find any mid-chip solder balls anywhere.

Out of curiosity I called my stencil vendor and asked them if they did any
reduction to the apertures as standard to the gerbers I send, and they said
no. The only reductions that they do are the ones that I specify, and I do
occasionally, or I have some special footprint that I want to see, like for
Teledyne GRF relays for example.  But as a rule I leave all the passive
apertures alone.

Like I said, in my case with a water soluble paste and a 4-mil thick stencil
and no homeplates, I very rarely see mid-chip solder balls.

Steve

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Phil Bavaro
Sent: Tuesday, May 01, 2012 1:28 PM
To: [log in to unmask]
Subject: Re: [TN] Homeplates on 4 mil thick stencils?

Steve,

I would check your wrap around termination capacitors.   There are many ways
to skin that cat and I suspect your paste aperture is already less than
1-to-1.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
Sent: Tuesday, May 01, 2012 7:28 AM
To: [log in to unmask]
Subject: Re: [TN] Homeplates on 4 mil thick stencils?

Hi Richard,

I just looked closely at some product that we were running today that's
using a 4-mil stencil (with no homeplates), and I don't see any mid-chip
solder balls, and I looked at where they would most likely occur if there
were to be any:

http://stevezeva.homestead.com/4-mil_no_homeplate.JPG

I can't say that we NEVER have any, sometimes it happens, like when the
wrong sized part is used on a footprint designed for something else (oh
wait, that never happens!). But overall, usually don't see them when we use
a 4-mil thick stencil.

Steve

-----Original Message-----
From: Stadem, Richard D. [mailto:[log in to unmask]]
Sent: Monday, April 30, 2012 3:56 PM
To: TechNet E-Mail Forum; Steve Gregory
Subject: RE: [TN] Homeplates on 4 mil thick stencils?

Steve,
Somewhat related to the other discussion on cleaning of no-clean:
Do you wash the assemblies after reflow, and is that why you do not see any
mid-chip solder balls?
Do you wash any CCAs that have been processed with a no-clean solder paste
or no-clean wire solder?

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
Sent: Monday, April 30, 2012 2:42 PM
To: [log in to unmask]
Subject: Re: [TN] Homeplates on 4 mil thick stencils?

BTW I forgot to add I don't homeplate anything...

Steve

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
Sent: Monday, April 30, 2012 3:16 PM
To: [log in to unmask]
Subject: Re: [TN] Homeplates on 4 mil thick stencils?

Hi Ioan,

We use 4-mil thick stencils quite often and I don't see mid-chip balling...

Steve

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Ioan Tempea
Sent: Monday, April 30, 2012 2:54 PM
To: [log in to unmask]
Subject: [TN] Homeplates on 4 mil thick stencils?

Dear Technos,

 

It is my first 4 mil stencil and I was wondering if mid-chip balling is
still an issue at this thickness (no-clean process). Should I still
homeplate the apertures of passives, as I fear insufficient solder?

 

Thanks,

 

Ioan Tempea, ing.
Ingénieur Principal de Fabrication / Senior Manufacturing Engineer T |
450.967.7100 ext.244 E | [log in to unmask] <mailto:[log in to unmask]> W |
www.digico.cc <http://www.digico.cc/> 

 
 N'imprimer que si nécessaire - Print only if you must

 


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

----------------------------------------------------------------------------
--
This message and any attachments are solely for the use of the addressee and
may contain L-3 proprietary information that may also be defined as USG
export controlled technical data. If you are not the intended recipient, any
disclosure, use or distribution of its content is prohibited. Please notify
the sender by reply e-mail and immediately delete this message and any
attachments.




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2