Phil Nutting <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Phil Nutting <[log in to unmask]>
Date:
Thu, 29 Mar 2012 12:04:09 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (1 lines)
Yup, that is what we live with on a regular basis.  Been doing it for 30+ years.

Phil

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Blair Hogg
Sent: Thursday, March 29, 2012 11:36 AM
To: [log in to unmask]
Subject: Re: [TN] Hi Voltage Board Design

Oh, this brings back memories (not all good) of a time long ago when I worked for a company that made display units for aircraft.

30kV supplies 2/3 the size of a standard home construction brick, maybe a little smaller, probably why we called them "bricks"

The boards had routed areas in between the different nets to provide for enough isolation. We had to solder all components first, inspect per mil-std, the add solder to each joint until it was a nice round ball.

Tested in an inert high dielectric liquid, then potted with high dielectric potting material, and still had arcing and corona. Dig out potting material, replace or resolder components, retest, repot, test again. Talk about fun.

I think your best bet is to hire someone with experience. Training program? The design engineers trained our production personnel and we learned with time what to do and what not to do.

Blair


On Tue, 27 Mar 2012 17:10:28 -0500, William Noel <[log in to unmask]> wrote:

>Hello all - Is anyone aware of a good training program that addresses design of high voltage pcb's?  I'm a little out of my comfort zone with regard to hi-voltage spikes, switching and the subsequent affect on other areas of the board.  Thanks in advance for any advice.


Note: All the information contained in this e-mail and its attachments is proprietary to Kaiser Systems, Inc. and it may not be reproduced without the prior written permission of sender.  If you have received this email in error, please immediately return it to sender and delete the copy you received.


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 