Hi Mickey,

On occasion heavy plating can cause a tendency for interconnect
separation in HDI applications. The barrel of the hole becomes so strong
and rigid that it does not flex during thermal excursions associated
with assembly. This rigidness causes more stress to the outer layer,
layers 2/3 and N-1/N-2, internal interconnections. If the
interconnections are weak then you can get a separation. 

This is rare but it can occur.

We have found that .0012" is the ideal thickness. More or less than
.0012" is a reliability liability.

Sincerely,  

Paul Reid 
Program Coordinator  

PWB Interconnect Solutions Inc. 
235 Stafford Rd., West, Unit 103 
Nepean, Ontario Canada, K2H 9C1 

613 596 4244 ext. 229  

Skype paul_reid_pwb 
[log in to unmask] 

 


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Mickey Weiner
Sent: March 1, 2012 9:00 AM
To: [log in to unmask]
Subject: Re: [TN] Excessive Copper Plating

Does it cause any assembly issues? or reduce the board reliability?

Best Regards
Mickey Weiner
972-8-9774808



On Thu, Mar 1, 2012 at 1:54 PM, William Noel <[log in to unmask]>
wrote:

> Hello all - We call out a minimum of .001 inches of copper plating on
the
> walls of our holes in our standard fabrication notes.  We don't
mention any
> min or max on exposed lands and lines. We recently received a board
that
> upon cross-section analysis we discovered it had an additional .005
inches
> of copper plated up on the top and bottom of the board.  We are
considering
> listing a maximum in our drawing notes as follows:  "PLATING PROCESS
SHALL
> NOT PRODUCE MORE THAN AN ADDITIONAL .0025 INCHES OF COPPER ON EXPOSED
LANDS
> AND LINES."  Anyone have any comments or suggestions for us?  Thanks
in
> advance.
>

CONFIDENTIALITY
This e-mail message and any attachments thereto, is intended only for
use by the addressee(s) named herein and may contain legally privileged
and/or confidential information. If you are not the intended recipient
of this e-mail message, you are hereby notified that any dissemination,
distribution or copying of this e-mail message, and any attachments
thereto, is strictly prohibited.  If you have received this e-mail
message in error, please immediately notify the sender and permanently
delete the original and any copies of this email and any prints thereof.
ABSENT AN EXPRESS STATEMENT TO THE CONTRARY HEREINABOVE, THIS E-MAIL IS
NOT INTENDED AS A SUBSTITUTE FOR A WRITING.  Notwithstanding the Uniform
Electronic Transactions Act or the applicability of any other law of
similar substance and effect, absent an express statement to the
contrary hereinabove, this e-mail message its contents, and any
attachments hereto are not intended to represent an offer or acceptance
to enter into a contract and are not otherwise intended to bind the
sender, Sanmina-SCI Corporation (or any of its subsidiaries), or any
other person or entity.


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud
service.
For more information please contact helpdesk at x2960 or
[log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2