Before you go through the expense and effort of doing DI to clean and rinse
try doing a tap clean and rinse WITH a blow off cycle. Have some ionic
contamination tests run afterwards, they will be very clean if you have a
good blow off.

Washing with Di water is kind of silly, how long does Di water remain DI
after a wash of dirty boards start?  Maybe 100 ms? Wash with tap.

Rinse in DI might help but a blow off of tap water leaves only tiny amounts
of material even with very hard tap water. It really depends on water
entrapment issues and then even a rinse is questionable.

Try something simple and measure.

Bob K.



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Terry Munson
Sent: Saturday, January 07, 2012 7:44 PM
To: [log in to unmask]
Subject: Re: [TN] Cleaning water soluble fluxþ

They should look at DI water steam to clean and rinse.  We have effectively
cleaned 2331-ZX flux. With stop steam cleaning. Call me at 765-457-8095.  

Terry Munson
Foresite
765-457-8095


On Jan 7, 2012, at 6:36 PM, Gary Bremer <[log in to unmask]> wrote:

> I am presently working as an contractor for the next few months then back
to unemployment, last place I worked was Jet Propulsion Laboratory on the
Mars Science Laboratory.  These are lighted panels for various aircraft and
the company policy is for J-STD-001/IPC-A-610 Class 3  The failure is with
miniature T-1 lamps that stop working after going through an baking process.
Other boards that use these lamps but use RMA flux do not have this problem,
I suspect the cleaning process and the flux.  They do not check ionic
contamination and handle the boards with bare hands and the operators even
know when components are ESD sensitive or not.  I have recommended they
change the cleaning process to an Aqueous type batch cleaner but this cost
money which they do not wish to spend.  Their process person believes that
their process is fine and something else is causing the problem (bad lamps,
forming lamp leads, etc.).  This goes against all my knowledge and training.
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 16.0 To 
> unsubscribe, send a message to [log in to unmask] with following text in 
> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt 
> or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET 
> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the 
> posts: send e-mail to [log in to unmask]: SET Technet Digest Search the 
> archives of previous posts at: http://listserv.ipc.org/archives For 
> additional information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> -----------------------------------------------------

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives For additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2