You don't state the nature and type of component failures: corrosion,
dendrites etc. However, the spec sheet is right: BIG mistake not to
clean this type of flux correctly. You must wash the boards thoroughly
all over and follow by an adequate number of good rinses. If your tap
water is not too hard, you may get away with just the last rinse or two
as DI.
You should also state whether the boards are required for hi-reliability
(space, avionics, military etc.) apps. If so, you need some form of
process control, such as ionic contamination testing, after qualifying
the process with ion chromatography and SIR/ECM testing.
Brian
On 07/01/2012 06:57, Gary Bremer wrote:
> Where I am working presently they are having component failures that are soldered with water soluble flux and solder. I observed their cleaning process and they are using room temperature distilled water and spot cleaning the solder joint only. Any opinion on this cleaning process pro/con? The flux that is being used 2331-ZX which has 2.2% halides. The tech data sheet for this states that DI-water of distilled water heated to 130° to 150° Fahrenheit and flush the area.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 16.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|