We have seen solder paste fail within its specified shelf life. The thread I
mentioned as worthwhile in the archive discusses the various failure modes.

In my experience early failures involve the solder balling, hot slump, and
poor printing especially when pushing limits, small apertures, and less than
optimal aspect rations. This especially true with pastes designed for
dispensing.

Guy

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steven Creswick
Sent: Monday, January 16, 2012 2:47 PM
To: [log in to unmask]
Subject: Re: [TN] Expired Solder Paste

Matthias,

I also have used polymers and solder well beyond their expiration date FOR
PERSONAL USE with very good success.

For me the critical aspect of being able to trust the material is knowing
that ONLY I have been into it.  If someone else were to get into my stash as
well, I would not be as confident of the materials characteristics.

You likely have the same observations.

FWIW


Steve Creswick
Sr Associate - Balanced Enterprise Solutions
http://www.linkedin.com/in/stevencreswick
                         616 834 1883



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Matthias Mansfeld
Sent: Monday, January 16, 2012 1:37 PM
To: [log in to unmask]
Subject: Re: [TN] Expired Solder Paste

On 16 Jan 2012 at 8:17, Stadem, Richard D. wrote:

> You can re-certify expired solder paste per J-STD-005 section 6.0.
> Used the form attached therein, and follow the appropriate test
> methods (also listed at the end of J-STD-005, #2.4.34, 2.4.34.1,
> 2.4.34.2, 2.4.34.3 for the viscometer you wish to use. You should
> always perform first article testing, monitor your PPMO, etc., and
> document all product run with the re-certified paste.

For what it's worth, a good solder paste, stored under good
conditions may work well even years after expiration. Been there,
done that without re-certification (don't worry, no customer
projects, just some own DIY-stuff....). For this stuff I use still
the same 1kg-jar with old Sn63Pb Alpha RMA390D3K from 2003.... prints
well, tacky like new, and visually perfect, shiny solder joints...
even 8 years after expiration date.

Best regards
Matthias Mansfeld
--
Matthias Mansfeld Elektronik * Leiterplattenlayout
Neithardtstr. 3, 85540 Haar; Tel.: 089/4620 093-7, Fax: -8
Internet: http://www.mansfeld-elektronik.de
GPG http://www.mansfeld-elektronik.de/gnupgkey/mansfeld.asc


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2