Well, from what I can tell comparing the data sheets,
the ITEQ IT-158 has a LOWER peel strength than the Grace MTC-97,
(Iteq is around 7-8? Grace is 11?)
And if you are using low-profile copper clad, it will be even lower
sorry I can't help more than that,
Jack
.
On Thu, 12 Jan 2012 13:24:40 -0700, Woolley, Mark D. (Mark) <[log in to unmask]> wrote:
>Let me add a bit more information on this issue.
>1. The material we are having issues with is Iteq IT-158. We are
>not seeing any issues with any of the other laminates we are using such
>as Grace MTC-97. The Iteq material has higher Tg, Td and pull
>strength per specification than the Grace MTC-97 material.
>2. The pad layout is identical across the product line. This
>includes the distance to the edge of the panel. The pads that are
>lifting are on the outside of the laminate. No internal
>delaminations have been seen in the cross sections I have made. Internal
>delamination si not suspected because the product operates when it is
>connected back together.
>3. The reflow profile is for Pb-free soldering using SAC305 solder.
>The peak temperatures, duration of the temperature and time above
>liquidus is the same on all reflow profiles of similar products.
>
>So I don't think the design is at fault, nor the processing at the
>assembly house. The pads are for 8-pin RJ-45 jacks using a standard
>pattern.
>
>I am seeing a ring of cleared copper on the PWB side of the pulled pad.
>This is troubling me because I can think of no reason it should be there
>unless the etchant was able to get beneath the copper pad. I can post
>an image if someone will be so good as to point me to the picture upload
>page. (much appreciated).
>
>
>mark
>Mark Woolley |PTRL Laboratory | Avaya | 1300 West 120th Ave |
>Westminster, CO 80234 USA |
>Voice (Lab): (303) 538-2166 | email: [log in to unmask] |
>
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|